CJKR Marine Packaged Air Conditioner - Marine Air Conditioner - Hi-sea

CJKR Marine Packaged Air Conditioner

CJKR Marine Packaged Air Conditioner

Overview

CJKR marine packaged air conditioning unit has two types, which are two cooling typecooling and heating type. The cooling type air condition is mainly composed of air filter, air cooler, marine centrifugal fan, refrigerating compressor, marine high-efficiency condenser, liquid supply solenoid valve, thermostatic expansion valve, electrical control cabinet and instrument cabinet etc. Diffusion box and mixing box are used as the associated equipment of the unit, the opening position and dimension of their nozzles will be arranged as per the requirements of the user.

Cooling and heating type air condition unit is formed by adding an additional set of heating device based on the cooling type air conditioning unit.

All components of this unit are already assembled by the manufacturer; also pressure test and vacuum test for cooling system are already done. Sufficient amount of R404A gas is filled in.



Main Technical Parameters

Type CJKR-35 CJKR-46
Cooling Capacity Kw 35 46
Adjustable Range / /
Compressor Motor
Power
Kw 8.5 12
Regenerating
Medium
R22 ( R134a, R404A, R407c )
Heating Capacity Kw 24 36
Heating Medium Electric Heater
Steam
Consumption
kg/h / /
Air Flow m3/h 3700 4200
Fan Motor Power Kw 3 5.5
External Static
Pressure
Pa 900 900
Cooling Water Medium ≤32℃(sea water/≤36℃(Fresh Water
Cooling Water
Flow
m3/h 10 13.5
Cooling Water
Press. Drop
KPa ≤50 ≤50
Protection HV. LV. Water Pressure. Overload. Electric Heating Over-temp. Safety Valve. Power Supply Faults
Power Supply AC380V 3Ph 50Hz / AC 440V 3Ph 60Hz
Weight kg ~1100 ~1200

Type CJKR-58 CJKR-70 CJKR-82 CJKR-93 CJKR-105 CJKR-116 CJKR-151 CJKR-175 CJKR-186 CJKR-210
Cooling Capacity Kw 58 70 82 93 105 116 151 175 186 210
Adjustable Range 0-50%-100% 0-66%-100% 0-50%-75%-100%
Compressor Motor
Power
Kw 15 17.5 19 23 27 30 37.5 45 56.25 60
Regenerating
Medium
R22 ( R134a, R404A, R407c )
Heating Capacity Kw 70 82 93 107 116 134 167 187 215 232
Heating Medium 0.3~0.4 MPa Steam
Steam
Consumption
kg/h 139 162 184 210 228 263 328 366 423 480
Air Flow m3/h 5000 6200 7200 8200 9000 10500 13100 15100 16000 18000
Fan Motor Power Kw 5.5 7.5 11 11 15 15 15 22.5 30 37
External Static
Pressure
Pa 1050 1200 1500 1570 1500 1500 1600 1800 1800 1800
Cooling Water Medium ≤32℃(sea water/≤36℃(Fresh Water
Cooling Water
Flow
m3/h 15 20 23.5 25 29 33 42 48 54 60
Cooling Water
Press. Drop
KPa ≤50 ≤50 ≤50 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70
Protection HV. LV. Water Pressure. Overload. ElectricHeating Over-temp. Safety Valve. Power Supply Faults
Power Supply AC380V 3Ph 50Hz / AC 440V 3Ph 60Hz
Weight kg 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200

Type CJKR-58B CJKR-70B CJKR-82B CJKR-93B CJKR-105B CJKR-116B CJKR-151B CJKR-175B CJKR-186B CJKR-210B
Cooling Capacity Kw 58 70 82 93 105 116 151 175 186 210
Adjustable Range 0-50%-100% 0-66%-100% 0-50%-75%-100%
Compressor Motor
Power
Kw 15 17.5 19 23 27 30 37.5 45 56.25 60
Regenerating
Medium
R22 ( R134a, R404A, R407c )
Heating Capacity Kw 70 82 93 107 116 134 167 187 215 232
Heating Medium 0.3~0.4 MPa Steam
Steam
Consumption
kg/h 139 162 184 210 228 263 328 366 423 480
Air Flow m3/h 5000 6200 7200 8200 9000 10500 13100 15100 16000 18000
Fan Motor Power Kw 5.5 7.5 11 11 15 15 15 22.5 30 37
External Static
Pressure
Pa 1050 1200 1500 1570 1500 1500 1600 1800 1800 1800
Cooling Water Medium ≤32℃(sea water/≤36℃(Fresh Water
Cooling Water
Flow
m3/h 15 20 23.5 25 29 33 42 48 54 60
Cooling Water
Press. Drop
KPa ≤50 ≤50 ≤50 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70
Protection HV. LV. Water Pressure. Overload. Electric Heating Over-temp. Safety Valve. Power Supply Faults
Power Supply AC380V 3Ph 50Hz / AC 440V 3Ph 60Hz
Weight kg 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200



Contact with us now