Explosion Proof Fire Damper - Marine Manual Fire Damper - Hi-sea

Explosion Proof Fire Damper

Explosion Proof Fire Damper

1. Features:
Our fire damper are especially designed for sea environment, and widely used for navy vessels, off-shore platform and underground projects etc. The fire damper could effectively hinder hydrosphere and fog in duct, and work well in this environment.
2. Main technical parameter:

Iterm

Types

Manual fire damper

Electrical fire damper

Pneumatic fire damper

Fusing temp.

70±3

70±3

70±3

Closed time

2s

1s

2s

Air leakage ate

5m³/m².h

5m³/m².h

5m³/m².h

Air source pressure

---

---

Compressed air of

0.5~0.8MPa

Control voltage

---

DC24V/AC110V/AC220V

Protection degree

---

IP44/IP56/IP65/IP67

Explosion-proof degree

---

ExdBT~BT6 ExdCT4~CT6

3. Configuration Options:

Features

Control mechanism

Electric

It can be manually operated on-site and can be controlled remotely.

Pneumatic

It can be manually operated on-site and can be controlled remotely. Pneumatic fire dampers are generally installed in hazardous areas.

Shape

Round/Rectangle

Explosion-proof requirements

Explosion-proof

For use in hazardous areas, containing explosive gases

Control Voltage

DC24V/AC110V/AC220V

Protection Degree

IP44/IP56/IP65/IP67

Explosion-proof Degree

ExdIIBT4~BT6 ExdIIC4~CT6

4.
Specific Difference Between Us and Other Suppliers:

Comparison

Product Picture of other low quality supplier


Product Picture of our factory


Other low quality supplier

Consequence

Our Factory

Consequence

Air leakage does not meet the requirements

Excessive air leakage from fire dampers will cause major safety hazards

Airtight performance is selected according to requirements

The air leakage meets the requirements, and the product is safer to use

The installation accuracy of the connecting rod between the baffles is not enough

As a result, when the fire damper is closed, the shutter still cannot be completely closed.

The connecting rod between the baffles is installed with high precision

When the fire damper is closed, the shutter can be fully closed.

The fire rating does not meet the requirements

It is easy to leave a safety hazard

Select as required

Product use more assured, longer service life

The thickness of the damper shell does not meet the requirements

The casing is prone to breakage

The thickness selection of the damper shell The regulations of each classification society are consistent with the SLOAS requirements

The shell meets the requirements, and the damper can be used for a longer time

5.Our Inventory:


6. IACS Certificate: KR, DNV▪GL, CCS, ABS, CE, LR, BV