Marine Black Water Treatment Plant - Marine Sewage Treatment Plant - Hi-sea

Marine Black Water Treatment Plant

Marine Black Water Treatment Plant

1. Marine Black Water Treatment Plant General:

The marine black water treatment plant belongs to the key devices for prevention of pollution form ships in seas and oceans according to the revised Annex IV of the International Convention of the Prevention of Pollution (MARPOL 73/78). The resolution MEPC. 2 (VI) adopted on 3 December 1976 is the present guidelines on implementation of effluent standards and performance tests for STP, which is called old standards. This device is according to the resolution MEPC. 159(55) enacted on 13 October 2006, which is called new standards. The convention (MARPOL 73/78) provides that all STPs installed on board on or after 1 January 2010 should meet the resolution MEPC159(55).
SWCM series: follow the IMO new standard MEPC159(55).

Main Parts

No.

Name

Qty.

Remark

1

Base

1set

channel steel

2

Body (include aeration tank, contact tanksediment tankdisinfection tank

1set

Assembly

3

Crushing pump

1set

Assembly

4

Air pump

1set

Assembly

5

Dosing pump

1set

Assembly

6

Control box

1set

Assembly

7

Pipe fittings

1set

Assembly


2. Marine Black Water Treatment Plant Principle Description:

This marine sewage treatment plant adopts the principle of Activated Sludge, Bio-contact Oxidation and Membrane Biological Reactor (MBR) to digest organic pollutant. MBR can treat organic pollutant efficiently, drastically and cleanly to insure the effluent can meet the requirements of the resolution MEPC. 159 (55) and other much harder requirements.

3. Configuration Comparison

crushing discharge pump


Brand

Foreign Famous brand

Domestic Brand

Pro& Cons

Long service life, stable operation and high processing efficiency.

The pump body is fragile, the service life is short, easy to damage, and the work is unstable.

Air pump

Brand

Foreign Famous brand

Domestic Brand

Pro& Cons

Long service life, stable operation and high processing efficiency.

The pump body is fragile, the service life is short, easy to damage, and the work is unstable.

MBR Membrane

Brand

Foreign Famous brand

Domestic Brand

Pro& Cons

Long service life, lower replacement costs

Short service life and high replacement cost

Disinfection device


Brand

UV

Medicine

Pro& Cons

Environmentally friendly, efficient, safe to operate, and does not produce harmful chemicals. However, the power consumption is large, and the UV lamp needs to be replaced regularly.

Economical and effective, with follow-up disinfection effect. But it is ineffective for some virus spores, produces odor, is affected by pH, and has disinfection by-products



3. Main Products:

Marine Black Water Treatment Plant


10 Persons Black Water

Treatment Plant


15 Persons Marine

Sewage Treater


20 Persons Black Water

Treatment Plant


25 Persons Marine

Sewage Processer


40 Persons Wastewater

Treatment Plant


50 Persons Biochemical

Sewage Treatment Plant


60 Persons Sewage

Treatment Equipment


80 Persons

Sewage Treater


100 Persons

Waste Water Treater


120 Persons

Sewage Processer


150 Persons

Wastewater Treater


200 Persons Sewage

Treatment Plant


250 Persons

Wastewater Processor


300 Persons Wastewater

Treatment Equipment


400 Persons

Waste Water Processor


600 Persons Black Water

Treatment Plant

4. Marine Black Water Treatment Plant Drawing & Technical datas:


Model

SWCM(I)

15

20

25

30

40

50

60

80

100

120

150

200

250

300

400

Average load

(L/d)

1190

1540

1890

2310

3080

3780

4480

6020

7700

9100

11200

14700

18200

23100

30800

Peak load

(L/h)

149

193

237

289

385

473

560

753

963

1138

1400

1838

2275

2888

3850

Organic load

(kgBOD5/d)

0.595

0.77

0.945

1.155

1.54

1.89

2.24

3.01

3.85

4.55

5. 6

7.35

9.10

11.55

15.4

Rated Capacity

(persons)

15

20

25

30

40

50

60

80

100

120

150

200

250

300

400

Max capacity

(persons)

17

22

27

33

44

54

64

86

110

130

160

210

260

330

440

Electricity

AC 380V/50Hz/3φ, AC 415V/50Hz/3φ, AC 440, 60Hz/3φ, etc.

Power (kW)

2.5

2.5

2.5

2.5

3.0

3.0

3.5

4.0

4.0

4.0

6.0

6.0

7.0

9.0

11

Outline Size

(mm) L×W×H

1870

×

1200

×

1450

1680

×

1400

×

1570

1890

×

1400

×

1560

1980

×

1500

×

1650

2320

×

1600

×

1700

2320

×

1700

×

1880

2650

×

1700

×

1860

2800

×

1900

×

2090

2800

×

2100

×

2300

3030

×

2100

×

2300

3090

×

2250

×

2390

3640

×

2250

×

2390

3890

×

2450

×

2580

4790

×

2450

×

2600

5980

×

2450

×

2600

Dry weigh (kgs)

1000

1000

1100

1200

1300

1450

1600

1850

2200

2300

2800

3000

3300

3700

4200

Wet weight (kgs)

2283

2640

2740

3500

4400

5073

5270

6517

8268

9166

11340

13267

16538

20357

25417

Effluent standard

BOD5≤25 Qi/Qe mg/L, COD≤125Qi/Qe mg/L, TSS≤35 Qi/Qe mg/L, coliform≤100/100ml, PH68.5, CL2≤0.5mg/L

5. Sewage discharge standard

MEPC.159(55)

old

MEPC.227(64) new

USCG

Alaska

TSS        (mg/l)

50

35

150

30

BOD5      (mg/l)

50

25

No requirement

30

COD       (mg/l)

No requirement

125

No requirement

No requirement

Coliform (/100ml)

250

100

200

20

PH

6~9

6`8.5

No requirement

6~9

Residual chlorine        (mg/l)

0.5

No requirement

10

Test Days (day)

10

10

10

30



5. Marine Black Water Treatment Plant Advantages:

(1) Adopting horizontal circular design, ellipse closures on both ends, pressure resistance and compact structure.

(2) The device is adopted auto-control, and compliance with the requirement of 24-hours unattended cabin.

(3) Adopting the 'MBR' technology, allow devices to narrow the size, and solve the conflict of small space of cabin, but big volume of device.

(4) The intermittent aeration in bio-membrane tank and hollow fiber membrane tank, form the process of 'aerobic - anoxic', and resolve the problem of 'nitrogen and phosphorus removal'.

(5) The device is adopting the principle of air-lifting to transfer the sludge from sediment tank and membrane tank to aeration tank, mealtimes the pump stops and air never stopped, so as the scale on the membrane surface comes down. Due to back flushing and clean the membrane online USD technology patent, so the life of membrane can be prolonged at least 8 to 9 years.

(6) "On-line" cleaning technology, making the dirt on membrane off automatically, recover membrane flux. It can be solved the problem of opening the cleaning or replacement of membrane difficultly caused by the small space in cabin.

(7) The effluent after further treatment can be reached at the requirement of water reuse.

For more information of the specification, please do not hesitate to contact us!