Marine Nitrogen Ballast Water Treatment System - Ballast Water Management System - Hi-sea

Marine Nitrogen Ballast Water Treatment System

Marine Nitrogen Ballast Water Treatment System

Brief Introduction

This type of BWMS is modular design, flexible layout, and small maintenance space required; no more breeding of organisms in the ballast tank, suitable for Long and short voyage; nitrogen feeding and de-oxygenation can effectively delay bulkhead corrosion; membrane separation technology reduces sediments in ballast tanks; energy consumption is only 1/3 of other treatment systems, which is the lowest in the world, and no limitation on salinity , temperature, turbidity, and etc.

Main Products
Nitrogen Ballast Water Treatment Plant


200Ballast Water

Management


300 m³ Ballast Water Management System


400 m³ BWMS


500 m³ Ballast Water Treatment System


600 m³ Ballast Water

Management Plant


800 m³ Ballast Water Treatment Plant


1000 m³ Ballast Water System


1500 m³ Ships Ballast System


2000 m³ Ballast Water Management System


2500 m³ Ballast Water Treatment System


3000 m³ Ballast water Treatment Plant


4000 m³ Vessels Ballast System


50 m³ Ships Ballast System

Treatment Technology

Mechanical filtration - high pressure back flush to ensure flux;

Membrane separation - reducing sediments and delaying cleaning;

Nitrogen feeding and de-oxygenation - kill organisms and prevent corrosion.

Composition


1.Filter Units



It is used to remove organisms and solid particles greater than 50μm, and carry out High pressure and suction back flushing of the filter core under differential pressure or timer.

2.Membrane Separation unit



It is used to remove organisms and solid particles greater than10μm, and performing gas-water mixture back flush on the membrane elements under the control of differential pressure or timer.

3.Nitrogen Generator


The nitrogen generator uses air as the material and uses molecular sieves to selectively adsorb nitrogen and oxygen.

4.Control Unit

It has Automatic and manual control system operation, used to monitor the operation status of the system and record system operation information.

System Specifications

Type NB-
200 300 400 500 600 800 1000 1200 1500 1800 2000 2500 3000 4000
TRC 200 300 400 500 600 800 1000 1200 1500 1800 2000 2500 3000 4000
Configuration power (kW) 8.3 10 10 12.4 13.4 18.9 21.2 24.7 24.7 24.95 25.7 29.7 34.4 35.2
Salinity No limitation
Water temperature No limitation
Ambient temperature 0~55℃
Compressed air pressure 0.7MPa
Flow rate No limitation
Treatment Flow



Comparison of different treatment method

IACS Certificate Options: BV, CCS, NK, DNV. GL, IRS, ABS, LR, RMRS, RINA


Contact with us now

Our mail: hs@cqhisea.com

replace