YLG-3.0 Hydrophore Tank - Marine Hydrophore - Hi-sea

YLG-3.0 Hydrophore Tank

YLG-3.0 Hydrophore Tank

1. YLG-3.0 Hydrophore Tank Technical Requirements
(1) Flange Standard:CB/T46-1999 PN1.0;
(2) The shell cover thickness including the forming thinning;
(3) The system including security settings;
(4) Pipes and support same as the drawings.

2. YLG-3.0 Hydrophore Tank Outer Joint

Mark

Name

Size

Standard

a

relief outlet

DN32

b

Water Inlet

DN50

CB/T46-1999 PN1.0

c

Compressor Air Inlet

DN10

CB*53-80

d

Water Outlet

DN50

CB/T46-1999 PN1.0

3. YLG-3.0 Hydrophore Tank Design Datas

Working Pressure

0.6Mpa

Design Pressure

0.7Mpa

Working Temp.

0~45℃

Design Temp.

50℃

Main Materials

CCS-B/SS304/SS316

corrosion allowance

0.75mm

welded joint coefficient

0.6

Capacity

3.0m³

The relief valve pressure jump

0.63MPa

G.W.

865 Kgs (with standard export wooden case)

N.W.

775 Kgs