Fixed
Mid-high Pressure Water-based Local Fire Fighting System
Description:
This
system is mainly used to protect below parts of a ship: the main propulsion, the
internal combustion engine of driving generator, the front of the boiler, the incinerator
and the purifier of heating fuel oil. It applies appropriate pressure to water
through pump. The pressurized water will become water mist when it goes through
fire nozzle. The water mist can dilute fluid combustible, smother the fire,
cool fire scene and reduce heat radiation.
Product
Detail:
Model |
Working pressure(MPa) |
Nozzle type |
Installing height of nozzle(m) |
Max.horizontal protection distance of nozzle(m) |
Flow coefficient K of nozzle |
||
Max. |
Min. |
Max. |
Min. |
||||
YNXSWC3-10 |
10 |
3 |
XSWTC1.6/8 |
7 |
0.5 |
2.8 |
1.6 |
Drawing
of Fixed Mid-high Pressure Water-based Local Fire Fighting System: