8x19 Class Steel Wire Rope for Bridge
Description
With high tensile strength, resistant to corrosion and high performance, our various galvanized wire rope are used in bridge. This steel wire rope is also suitable for hoisting, etc.
Certificate & authority:
Certificate:ABS,LR,CE,CCS,BV,DNV
Standard:GB8919,GB/T 20067, ISO, ASTM, EN, JIS, etc.
Superiority:
1. High tensile strength
2. Anti-corrosion
3. High performance
4. Various galvanized types
5. Reliable and safe
Detail:
Common construction: 8×19S, 8×19W,8×25Fi, 8×26WS,8×31WS
Diameter:60-92 mm
Application: bridge, hoisting, etc.
Specification:
8x19 Class Steel Wire Rope for Bridge |
||||
8×19S+FC |
8×19W+FC |
8×25Fi+FC |
8×26WS+FC |
8×31WS+FC |
8×19S+IWR |
8×19W+IWR |
8×25Fi+IWR |
8×26WS+IWR |
8×31WS+IWR |
Parameter of 8×19 class wire rope for bridge :
Rope dia.(mm) |
Approx.weight (kg/100m) |
Nominal tensile strength grade of rope(MPa) |
||||||||||
1570 |
1670 |
1770 |
1870 |
1960 |
||||||||
Minimum breaking load of rope(kN) |
||||||||||||
FC |
IWR |
FC |
IWR |
FC |
IWR |
FC |
IWR |
FC |
IWR |
FC |
IWR |
|
60 |
1290 |
1570 |
1660 |
1960 |
1760 |
2080 |
1870 |
2200 |
1970 |
2330 |
2070 |
2440 |
62 |
1370 |
1670 |
1770 |
2090 |
1880 |
2220 |
1990 |
2350 |
2110 |
2490 |
2210 |
2610 |
64 |
1460 |
1780 |
1880 |
2230 |
2000 |
2370 |
2120 |
2510 |
2240 |
2650 |
2350 |
2780 |
66 |
1560 |
1890 |
2000 |
2370 |
2130 |
2520 |
2260 |
2670 |
2390 |
2820 |
2500 |
2950 |
68 |
1650 |
2000 |
2130 |
2510 |
2260 |
2670 |
2400 |
2830 |
2530 |
2990 |
2660 |
3140 |
70 |
1750 |
2130 |
2250 |
2600 |
2400 |
2830 |
2540 |
3000 |
2680 |
3170 |
2810 |
3320 |
72 |
1850 |
2260 |
2380 |
2820 |
2540 |
3000 |
2690 |
3180 |
2840 |
3350 |
2980 |
3520 |
74 |
1950 |
2380 |
2520 |
2970 |
2680 |
3160 |
2840 |
3350 |
3000 |
3540 |
3140 |
3710 |
76 |
2060 |
2510 |
2660 |
3140 |
2830 |
3340 |
3000 |
3540 |
3160 |
3740 |
3320 |
3920 |
78 |
2170 |
2650 |
2800 |
3300 |
2980 |
3520 |
3160 |
3730 |
3330 |
3940 |
3490 |
4130 |
80 |
2280 |
2780 |
2940 |
3480 |
3130 |
3700 |
3320 |
3920 |
3510 |
4140 |
3680 |
4340 |
82 |
2400 |
2920 |
3090 |
3650 |
3290 |
3890 |
3490 |
4120 |
3680 |
4350 |
3860 |
4560 |
84 |
2520 |
3070 |
3250 |
3830 |
3450 |
4080 |
3660 |
4320 |
3870 |
4570 |
4050 |
4790 |
86 |
2640 |
3220 |
3400 |
4020 |
3620 |
4270 |
3840 |
4530 |
4050 |
4790 |
4250 |
5020 |
88 |
2760 |
3370 |
3560 |
4210 |
3790 |
4470 |
4020 |
4740 |
4240 |
5010 |
4450 |
5250 |
90 |
2890 |
3520 |
3730 |
4400 |
3960 |
4680 |
4200 |
4960 |
4440 |
5240 |
4650 |
5490 |
92 |
3020 |
3680 |
3890 |
4600 |
4140 |
4890 |
4390 |
5180 |
4640 |
5480 |
4860 |
5740 |
Note:The total Min.breaking force of wire=Min. breaking load of rope ×1.226(for fiber core) or ×1.374(for steel core) |