Introduction:
Pressure gauges with electric connections are commonly used in marine applications for monitoring pressure in various systems, such as hydraulic systems, fuel systems, or compressed air systems. These gauges typically feature an electric sensor or transducer that converts the pressure into an electrical signal, which can then be displayed or transmitted to other devices for monitoring or control purposes.
Model Sign:
S: three pin
Install:
Z- Axial Type
ZT- Axial Side Type
T- Radical Back Side Type
TF- Radical Back Square Side Type
Dial dia:
Φ 60
Φ75
Φ 100
Φ 150
N: Anti-vibration type
Y- Pressure Gauge
YZ- Vacuum Pressure Gauge
Z- Vaccun Gauge
YX- Pressure Gauge with electric connection
YA- Ammonia Gauge
YC- Marine Pressure Gauge
Technical Specification:
Dial diameter |
Type and feature |
Model code |
Measuring Range |
Accuranse |
Connection |
Material |
|
Radical type |
Ⅰ |
|
0~0.06 -0.1~0 |
2.5 |
M14×1.5 |
Iron |
|
60 |
Radical back side type |
Ⅱ |
T |
||||
75 |
Radical back square |
|
TF(TY) |
||||
1.6 |
|||||||
100 |
Axial type |
Ⅳ |
Z |
||||
150 |
Axial side type |
Ⅲ |
ZT |
||||
Pressure Gauge's Mounting Dimensioon
D |
D1 |
A |
B |
d0 |
d1 |
60 |
82 |
|
|
72 |
Φ4.5 |
75 |
98 |
77 |
39 |
88 |
Φ4.5 |
100 |
125 |
|
|
116 |
Φ4.5 |
107 |
135 |
|
|
118 |
Φ6 |
150 |
183 |
|
|
162 |
Φ6.5 |
Pressure Gauge Connection Thread Dimension
Dial diameter |
Connection Dimension |
||
d |
L(mm) |
d1(mm) |
|
60 |
M14×1.5 |
12 |
Φ5 |
75 |
G³/8" |
16 |
Φ5.5 |
100 |
M20×1.5 |
20 |
Φ5.5 |
150 |
Thermometer drawing: