    200 m³ Ships UV Ballast System

    200 m³ Ships UV Ballast System

    Application

    BWMS is a key international measurement for environmental protection that aims to stop the spread of potential invasive aquatic species in ships' ballast water enters into force. Being a relatively more mature disinfection technology, compared to other disinfection technologies, ultraviolet disinfection does not produce active substances, does not pose an occupational hazard to crew, more economical and environmentally friendly.

    System Specifications

    Model Flow rate(m3/h) Horizontal Layout(L*W*H) Vertical Layout(L*W*H) Power Rating(KW)
    P-200 100-200 2480*1300*1926 1150*1150*2490 27/36
    Drawing and List


    No. Name Specification
    1 Auto-flushing filter Type: SJY200
    2 UV chamber Type: UV200
    3 Flow meter 200m³/h;4~20mA
    4 Sludge pump 21m³/h;4~20mA
    5 Filter Inlet Valve Pheumatic valve DN150 PN10
    6 Filter bypass valve Pheumatic valve DN150 PN10
    7 UV Outlet Valve Pheumatic valve DN150 PN10
    8 Hand valve DN150 PN10 WCB
    9 Hand valve DN150 PN10 WCB
    10 Hand valve DN80 PN10 WCB
    11 Sludge valve Pheumatic valve DN80 PN10
    12 System Bypass valve Pheumatic valve DN150 PN10
    13 Ballast Tank Outlet Valve Pheumatic valve DN150 PN10
    14 Ballast Tank Inlet Valve Pheumatic valve DN150 PN10
    15 Overboard valve Pheumatic valve DN150 PN10
    16 Filter Outlet Valve Pheumatic valve DN150 PN10
    17 Sampling Valve DN40
    18 Sampling Valve DN40
    19 D.P. Gauge 0~1bar;4~20mA
    20 UV Sensor 0~12000W/m³
    21 Temp. Sensor Pt-100;24VDC;0-500t
    22 Y type strainer Degree:6mm
    23 Backwash pump 3KW;2MPa

    System Operating Principles

    In the ballast process of the ship, the ballast water enters the ballast water management system from the ballast pump through the filter, then is treated by the MPUV (medium pressure Ultraviolet) reactor, and then enters the ballast tank. Through the filter; large inorganic particles, most zooplankton and phytoplankton will be removed to ensure the effectiveness of downstream MPUV disinfection. Ultraviolet irradiation at 200-280nm wavelength in MPUV reactor can cause damage to cells and realize disinfection of residual plankton, bacteria and viruses in ballast water.

    During de-ballasting, the ballast water is directly pumped into the MPUV reactor; by passing the Filter for secondary disinfection treatment before discharge.

    IACS Certificate Options: BV, CCS, NK, DNV, GL, IRS, ABS, LR, RMRS, RINA