ZRG-0.2 Steam Heating Hot Water Tank
Application
This series are suitable for heating water on the ship or platform, heated fresh water for crew use.
Drawing & Specifications
Model
0.2
Capacity (m3)
0.2
Working pressure(MPa)
0.6(60℃)
Design pressure (MPa)
0.7
Test pressure (MPa)
1.05
Safety valve open pressure(MPa)
0.63
Water inlet temperature(℃)
15
Water outlet temperature (℃)
65
Working temperature (℃)
0~65
Design temperature(℃)
80
Steam pressure (MPa)
0.3
Heating water capacity(kg/h)
450
steam consumption(kg/h)
45
The thickness of the external thermal layer(mm)
40
The thickness of outer galvanized sheet steel(mm)
0.7
This series hot water tank can be combined to use with fresh water pressure tank on board, that is to use fresh water in fresh water pressure tank to replenish this tank, and then heated by steam heating elements for usage of entire vessel.
Temperature adjusting valve: open and close it according to the set temperature control range.
Pressure gauge: to show the pressure in tank.
Thermometer: to show the water temperature in tank.
Safety valve: If the pressure in tank is more than 0.63MPa, the safety valve will open to release the pressure in tank.
Note: Never wind the raw material belts into the inlet of safety valve when installing the safety valve.
IACS Certificate Options: BV, CCS, NK, DNV, GL, IRS, ABS, LR, RMRS, RINA