Marine Nitrogen Ballast Water Treatment System
Brief Introduction
This type of BWMS is modular design, flexible layout, and small maintenance space required; no more breeding of organisms in the ballast tank, suitable for Long and short voyage; nitrogen feeding and de-oxygenation can effectively delay bulkhead corrosion; membrane separation technology reduces sediments in ballast tanks; energy consumption is only 1/3 of other treatment systems, which is the lowest in the world, and no limitation on salinity , temperature, turbidity, and etc.
Main Products
800 m³ Ballast Water Treatment Plant
2000 m³ Ballast Water Management System
2500 m³ Ballast Water Treatment System
3000 m³ Ballast water Treatment Plant
Nitrogen Ballast Water Treatment Plant
Treatment Technology
Mechanical filtration - high pressure back flush to ensure flux;
Membrane separation - reducing sediments and delaying cleaning;
Nitrogen feeding and de-oxygenation - kill organisms and prevent corrosion.
Composition
1.Filter Units
It is used to remove organisms and solid particles greater than 50μm, and carry out High pressure and suction back flushing of the filter core under differential pressure or timer.
2.Membrane Separation unit
It is used to remove organisms and solid particles greater than10μm, and performing gas-water mixture back flush on the membrane elements under the control of differential pressure or timer.
3.Nitrogen Generator
The nitrogen generator uses air as the material and uses molecular sieves to selectively adsorb nitrogen and oxygen.
4.Control Unit
It has Automatic and manual control system operation, used to monitor the operation status of the system and record system operation information.
System Specifications
Treatment Flow
Type
NB-
200
300
400
500
600
800
1000
1200
1500
1800
2000
2500
3000
4000
TRC
200
300
400
500
600
800
1000
1200
1500
1800
2000
2500
3000
4000
Configuration power (kW)
8.3
10
10
12.4
13.4
18.9
21.2
24.7
24.7
24.95
25.7
29.7
34.4
35.2
Salinity
No limitation
Water temperature
No limitation
Ambient temperature
0~55℃
Compressed air pressure
0.7MPa
Flow rate
No limitation
Comparison of different treatment method
IACS Certificate Options: BV, CCS, NK, DNV. GL, IRS, ABS, LR, RMRS, RINA