MARINE & OFFSHORE EQUIPMENT
- Dredging Equipment
- Marine Deck Machinery
-
Marine Mooring Equipment
-
Marine Anchor
- AC-14 HHP Anchor
- Admiralty Anchor
- Beldt Stockless Anchor
- Bruce Anchor
- Spek Anchor
- Danforth HHP Anchor
- Delta High Holding Power Anchor
- GB11579-89 Light Weight Anchor
- Hall Anchor
- High Holding Power Mastrosov Anchor
- Hot Dip Galvanized Anchor
- Japan Stock Anchor
- JIS Stockless Anchor
- Pool Anchor
- Single Fluke Anchor
- Stainless Steel Anchor
- Stevpris MK5 Anchor
- Stingray Anchor
- US Navy Stockless Anchor
-
Marine Anchor Chain
-
Marine Shackle
- Kenter Shackle
- D Type Joining Shackle
- Pear Shaped Shackle
- Anchor Swivel Shackle Type A
- Anchor Swivel Shackle Type B
- Buoy Shackle Type A
- Buoy Shackle Type B
- C Type Detachable Connecting Link
- D Shackle
- Forelock Shackle
- Anchor Chain Swivel Group
- Straight Shackle
- Anchor Shackle
- Marine Triangle Plate
- Anchor Chain Swivel
- Anchor Chain Joining Shackle
- Anchor Chain End Shackle
- Slim Kenter Shackle
-
Chain Chaser
-
Marine Bollard
-
Marine Chock
-
Marine Fairlead
-
Marine Chain Stopper
-
Marine Mooring Reel
-
Marine Towing Bracket
-
Mooring Rope
-
Marine Towing Hook
-
Marine Shark Jaw
- Marine Fender
-
Marine Buoy
- Marine Floating Pontoon Dock
-
Marine Anchor
- Aquaculture Equipment
- Marine Outfitting Equipment
- Marine Propulsion System
-
Marine Painting
-
Marine Auxiliary Machinery
- Marine Air Compressor
- Marine Air Receiver
- Marine Sewage Treatment Plant
-
Marine Diesel Generator Set
- Marine Oil Water Separator
- Ballast Water Management System
- Marine Hydrophore
- Marine Calorifier
- Seawater Desalination Plant
-
Marine Oil Separator
- Marine Fuel Oil Supply Unit
- Marine Heat Exchanger
-
Marine Hot Well Unit
-
Marine Incinerator
-
Marine Boiler
-
Marine Valve
- JIS Marine Valve
- DIN Marine Valve
- ANSI Marine Valve
- GB Marine Valve
- CB Marine Valve
- CBM Marine Valve
-
Marine Gate Valve
-
Marine Globe Valve
-
Marine Angle Globe Valve
-
Marine SDNR Valve
-
Marine Angle SDNR Valve
-
Marine Check Valve
-
Marine Storm Valve
-
Marine Butterfly Valve
-
Marine Quick Closing Valve
-
Marine Fire Valve
-
Marine Self Closing Valve
- Marine Valve Accessories
-
Marine Pump
- Marine Centrifugal Pump
- Marine Screw Pump
-
Marine Gear Pump
-
Marine Vortex Pump
-
Marine Ejector Pump
-
Marine Diaphragm Pump
-
Marine Piston Pump
-
Marine Fire Pump
-
Marine Emergency Fire Pump
-
Marine External Fire Pump
-
Marine Ballast Water Pump
-
Marine Fuel Pump
-
Marine Lubricating Oil Pump
-
Marine Bilge Pump
-
Marine Sewage Pump
-
Marine Domestic Water Pump
-
Marine General Pump
-
Marine Cargo Oil Pump
-
Marine Hand Pump
- Marine Pump Parts
- Marine Life-saving Equipment
- Fire-fighting Equipment
- Marine Cable
- Marine Electrical Equipment
- Marine HVAC
-
Labour Protection Appliance
- Marine Decorative Material
-
Marine Anode
- Marine Pipe Fitting & Flange
- Marine Instrument
- Ship Building Equipment
INDUSTRY EQUIPMENT
- Hoisting Equipment
- Welding Machine & Material
-
Cutting Machine
- Container Securing Fitting
- Link Chain
- Container & Storage Equipment
-
Diesel Generator Set
- Other Equipment and Tools
- Petrochemical Equipment
- Fiber Reinforced Plastics
- Polymer Materials
- Environmental Protection Series
- Geo-products and Building Materials
- Metal Mesh
- Steel Grating
-
Earthwork Teeth
-
Turnbuckle
STOCK LIST
Contacts
Tel:+86-23-67956606
FAX:+86-23-67956622
Email:manager@cqhisea.com
Working Time: 9:00--17:00
Working Day: Monday to Friday Website: www.cqhisea.com
Bilge Water Separation Plant
Bilge Water Separation Plant
1. Principle of Bilge Water Separation Plant
The device adopts the combination of 1st stage cone plate gravity and coalesce separator; 2nd stage fiber filter, and 3rd stage membrane permeation, in order to make the treated bilge water to reach the requirements of discharge standard of the Resolution of IMO MEPC.107 (49).
As shown in the enclosed drawing,bilge water comes into the 1st stage separator, inside it is a vacuum negative pressure stage by the suction of the feeding pump, and it effectively prevents the problem that the bilge water is difficult to be separated because of the emulsion caused by feed pump under pressure. The liquid coming out of Feeding pump is adsorbed and filtered by the 2nd stage fiber filter, and then goes into the 3rd stage membrane to reach the discharge standard.
There is a 15ppm bilge alarm in the ship cabin to measure the oil content of effluent. If it finds that the oil content of effluent is in an excess of limit, the oil content meter can make order to switch turn it into the 3rd stage, membrane treatment process.
The oil content meter will give an alarm if finds the oil content of effluent is above limit, and the unqualified water pneumatic three-way valve VS6 is opened automatically, so that the unqualified water is return to bilge, not to the overboard.
2. Bilge Water Separation Plant Technical Specifications
Type Technical Specifications |
YWC- |
|||||||||
0.25 |
0.50 |
1.00 |
1.50 |
2.00 |
2.50 |
3.00 |
4.00 |
5.00 |
||
Rated capacity (m3/h) |
0.25 |
0.50 |
1.00 |
1.50 |
2.00 |
2.50 |
3.00 |
4.00 |
5.00 |
|
oil content of the discharged water |
≤15ppm |
|||||||||
Power of the electric heater(kw) |
1kw |
3kw |
6 |
6 |
6 |
6 |
6 |
12 |
12 |
|
Electrical System |
AC 380V/50Hz/3φ, AC 415V/50Hz/3φ, AC 440/60Hz/3φ, AC 480V/60HZ/3φ (optional) |
|||||||||
Power of the electric motor |
0.37kw |
0.55kw |
0.75kw |
1.1kw |
1.1kw |
1.5kw |
1.5kw |
2.2kw |
2.2kw |
|
Suction head |
≤6m-H2O |
|||||||||
Pressure of the discharged water |
5-10m-H2O |
|||||||||
Outline Dimension(L×W×H)(mm) |
1000× 600× 1250 |
1100× 690× 1460 |
1050× 1000× 1620 |
1100× 1130× 1650 |
1900× 1120× 1700 |
1900× 1120× 1900 |
1700× 1500× 1900 |
2280× 1700× 1900 |
2590× 2000× 1900 |
|
base |
5# |
6# |
6# |
6# |
8# |
8# |
8# |
10# |
10# |
|
Weight |
Dry Weight |
400 |
600 |
800 |
1060 |
1260 |
1500 |
1800 |
2100 |
2500 |
|
Wet Weight |
550 |
900 |
1200 |
1650 |
2260 |
2800 |
3200 |
3900 |
4600 |
Applicable Vessel (KDWT) |
<1 |
1-5 |
5-10 |
10-30 |
30-50 |
50-100 |
100-200 |
100-300 |
>300 |
4. Certificates of Bilge Water Separation Plant: CCS, EC, BV, DNV.GL , KR, LR, ABS, RINA approvable.