MARINE & OFFSHORE EQUIPMENT
- Dredging Equipment
- Marine Deck Machinery
-
Marine Mooring Equipment
-
Marine Anchor
- AC-14 HHP Anchor
- Admiralty Anchor
- Beldt Stockless Anchor
- Bruce Anchor
- Spek Anchor
- Danforth HHP Anchor
- Delta High Holding Power Anchor
- GB11579-89 Light Weight Anchor
- Hall Anchor
- High Holding Power Mastrosov Anchor
- Hot Dip Galvanized Anchor
- Japan Stock Anchor
- JIS Stockless Anchor
- Pool Anchor
- Single Fluke Anchor
- Stainless Steel Anchor
- Stevpris MK5 Anchor
- Stingray Anchor
- US Navy Stockless Anchor
-
Marine Anchor Chain
-
Marine Shackle
- Kenter Shackle
- D Type Joining Shackle
- Pear Shaped Shackle
- Anchor Swivel Shackle Type A
- Anchor Swivel Shackle Type B
- Buoy Shackle Type A
- Buoy Shackle Type B
- C Type Detachable Connecting Link
- D Shackle
- Forelock Shackle
- Anchor Chain Swivel Group
- Straight Shackle
- Anchor Shackle
- Marine Triangle Plate
- Anchor Chain Swivel
- Anchor Chain Joining Shackle
- Anchor Chain End Shackle
- Slim Kenter Shackle
-
Chain Chaser
-
Marine Bollard
-
Marine Chock
-
Marine Fairlead
-
Marine Chain Stopper
-
Marine Mooring Reel
-
Marine Towing Bracket
-
Mooring Rope
-
Marine Towing Hook
-
Marine Shark Jaw
- Marine Fender
-
Marine Buoy
- Marine Floating Pontoon Dock
-
Marine Anchor
- Aquaculture Equipment
- Marine Outfitting Equipment
- Marine Propulsion System
-
Marine Painting
-
Marine Auxiliary Machinery
- Marine Air Compressor
- Marine Air Receiver
- Marine Sewage Treatment Plant
-
Marine Diesel Generator Set
- Marine Oil Water Separator
- Ballast Water Management System
- Marine Hydrophore
- Marine Calorifier
- Seawater Desalination Plant
-
Marine Oil Separator
- Marine Fuel Oil Supply Unit
- Marine Heat Exchanger
-
Marine Hot Well Unit
-
Marine Incinerator
-
Marine Boiler
-
Marine Valve
- JIS Marine Valve
- DIN Marine Valve
- ANSI Marine Valve
- GB Marine Valve
- CB Marine Valve
- CBM Marine Valve
-
Marine Gate Valve
-
Marine Globe Valve
-
Marine Angle Globe Valve
-
Marine SDNR Valve
-
Marine Angle SDNR Valve
-
Marine Check Valve
-
Marine Storm Valve
-
Marine Butterfly Valve
-
Marine Quick Closing Valve
-
Marine Fire Valve
-
Marine Self Closing Valve
- Marine Valve Accessories
-
Marine Pump
- Marine Centrifugal Pump
- Marine Screw Pump
-
Marine Gear Pump
-
Marine Vortex Pump
-
Marine Ejector Pump
-
Marine Diaphragm Pump
-
Marine Piston Pump
-
Marine Fire Pump
-
Marine Emergency Fire Pump
-
Marine External Fire Pump
-
Marine Ballast Water Pump
-
Marine Fuel Pump
-
Marine Lubricating Oil Pump
-
Marine Bilge Pump
-
Marine Sewage Pump
-
Marine Domestic Water Pump
-
Marine General Pump
-
Marine Cargo Oil Pump
-
Marine Hand Pump
- Marine Pump Parts
- Marine Life-saving Equipment
- Fire-fighting Equipment
- Marine Cable
- Marine Electrical Equipment
- Marine HVAC
-
Labour Protection Appliance
- Marine Decorative Material
-
Marine Anode
- Marine Pipe Fitting & Flange
- Marine Instrument
- Ship Building Equipment
INDUSTRY EQUIPMENT
- Hoisting Equipment
- Welding Machine & Material
-
Cutting Machine
- Container Securing Fitting
- Link Chain
- Container & Storage Equipment
-
Diesel Generator Set
- Other Equipment and Tools
- Petrochemical Equipment
- Fiber Reinforced Plastics
- Polymer Materials
- Environmental Protection Series
- Geo-products and Building Materials
- Metal Mesh
- Steel Grating
-
Earthwork Teeth
-
Turnbuckle
STOCK LIST
Contacts
Tel:+86-23-67956606
FAX:+86-23-67956622
Email:manager@cqhisea.com
Working Time: 9:00--17:00
Working Day: Monday to Friday Website: www.cqhisea.com
Fluoro-protein and Protein Foam Concentrate
Fluoro-protein and Protein Foam Concentrate
Description:
Fluoro-protein and protein foam fire extinguishing agent is based on protein foam fire extinguishing agent. It is formulated with appropriate addition of fluorocarbon surfactants. Compared with protein foam fire extinguishing agent, because of its reduced surface tension and interfacial tension, low shear stress, good fluidity, strong oleophobic ability, and high oil pollution resistance, the fire extinguishing time of this fire extinguishing agent is shortened by 1/3~ 1/2, it can use submerged jet to save large oil tank fires, and can be used in combination with dry powder fire extinguishing agents.
This product can be mixed with water in the ratio of 3:97 or 6:94 in low-expansion foam generating equipment to produce foam fire extinguishing. It is used for the rescue and prevention of large oil fires such as oil fields, oil depots, petrochemical enterprises, ships, and airports.
The technical performance indicators of this product are in accordance with the national
The product should be sealed and stored in a cool, dry and ventilated place indoors. The storage temperature should be lower than 45°C and higher than its minimum use temperature. The validity period is two years.
This product is suitable for fresh water and sea water, not affected by freezing and thawing, and can prepare cold-resistant products for you according to user needs
Standard& Certificate:
Standard: GB15308-2006 Foam Fire Extinguishing Agent; GB/T19001-2016/ISO 9001:2015; GB15308-2006;GB/T24001-2016/ISO 14001:2015; GB/T28001-2011/OHSAS 18001:2007; MSC.327(90); MSC.339(91; MSC.1/Circ.1312, etc.
Certificate: CCS
Specification:
Model |
Mixture ratio |
Solidification point & Applicable water category |
3%(FP) |
3% |
-20℃ sea water resistance |
6%(FP) |
6% |
-10℃ sea water resistance |
Item |
condition |
parameter |
Solidification point |
before temperature treatment |
0-4℃(eigenvalue) |
Freezing resistance & thawing resistance |
before and after temperature treatment |
no visible stratification and heterogeneous |
Fluidity |
before and after temperature treatment |
The flow rate of the foam liquid≥the flow rate of the standard reference liquid or the viscosity value of the foam liquid≤the viscosity value of the standard reference liquid |
Sediment (%) |
before aging |
≤0.25;Precipitate can pass through 180μm sieve |
After aging |
≤1.0;Precipitate can pass through 180μm sieve |
|
pH Value |
before and after temperature treatment |
6.0~9.5 |
Corrosion rate / [mg/(d.dm2)] |
before temperature treatment |
Q235A steel sheet: ≤15.0, LF21aluminum sheet: ≤15.0 |
Foaming expansion rate |
before and after temperature treatment |
The deviation from the eigenvalue≤1.0 or≤20% of the eigenvalue, which is determined by the larger of the above two differences |
The 25% drainage time |
before and after temperature treatment |
The deviation from the eigenvalue≤20% |
Fire extinguishing performance |
IIA Class |
fire extinguishing time ≤4min |
Anti-burn time ≥10min |