Gooseneck Air Ventilation - Marine Goose-neck Ventilation - Hi-sea

Gooseneck Air Ventilation

Gooseneck Air Ventilation

Introduction:

Gooseneck air ventilation is a type of air ventilation system that utilizes a flexible gooseneck duct to provide targeted airflow in specific areas. It is commonly used in various settings such as industrial facilities, laboratories, workshops, and commercial spaces where localized ventilation is required.

The gooseneck design refers to the flexible and adjustable nature of the duct. It consists of a rigid section at one end and a flexible, bendable section resembling a gooseneck, hence the name. This flexibility allows for easy positioning and directing of the airflow to specific areas, providing effective ventilation exactly where it is needed.

Gooseneck air ventilation systems are typically connected to an air extraction system, such as a fan or an HVAC (Heating, Ventilation, and Air Conditioning) system. The fan or HVAC system creates negative pressure that draws air from the surrounding space through the gooseneck duct, effectively capturing and removing airborne contaminants, fumes, or odors from the targeted area.

One of the key advantages of gooseneck air ventilation is its versatility. The flexible gooseneck duct can be easily adjusted to direct airflow in different directions, angles, or heights, allowing for precise control over the ventilation process. This feature makes it particularly useful in situations where fixed or rigid ducts may not be suitable or practical.

Gooseneck air ventilation systems are often equipped with additional features to enhance their functionality. These can include adjustable dampers to control airflow rate, filters to capture particulate matter, and noise reduction mechanisms to minimize operational noise.

Overall, gooseneck air ventilation offers an efficient and customizable solution for localized ventilation needs. By providing targeted airflow, it helps maintain air quality, remove contaminants, and ensure a safer and more comfortable environment in specific areas of use.

Specification

DN

airduct

Cover

padding

press plate

D

t

D1

t1

D1

D2

D2

D3

D4

100

108

4

118

6

118

48

48

78

63

114

6

124

8

124

54

54

84

69

8

150

159

4.5

170

6

170

100

100

130

115

168

6

178

8

178

108

108

138

123

8

200

203

6

213

6

213

143

143

173

158

219

6

229

8

229

159

159

189

174

8

250

245

6.5

255

6

255

185

185

215

200

273

6.5

283

8

283

213

213

243

228

8

300

299

7.5

309

6

309

239

239

269

254

325

7.5

335

8

335

265

265

295

280

9