JIS C3410 Individual Screen Control Cable - Marine Control Cable - Hi-sea

JIS C3410 Individual Screen Control Cable

JIS C3410 Individual Screen Control Cable

Cable Application:

The cable is fixed installation, used for Control, signal system in ship.


Cable Model:
250V MPY-S, FA-MPY-S 250V MPYC-S, FA-MPYC-S 250V MPYCY-S, FA-MPYCY-S


Cable Standards:
- Design guide : JIS C 3410(1999/2010)

- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)

- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)

- Max. conductor temperature :85


Cable Construction:

Classification Code Construction details
Conductor M Tinned Copper Wire JIS C3410
Insulation P EPR as per JIS C 3410
Individual Shield -S Tinned Copper Wire
Sheath Y PVC as per JIS C 3410
Armor C Galvanized steel wire braided

CB Tinned copper wire braided
Paint
The white paint should be painted uniformly
Covering Y PVC as per JIS C 3410


Color: Black













Recommendations Minimum Cable Bending Radius:

The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable

Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.

Installations Temperature:

Minimum recommended temperature of installations :

-10°C Ship wiring cable with PVC sheath

-20°C Elastomeric on/off shore cables

Installations Pulling Force:

The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.