JIS C3410 Collective Screen Control Cable - Marine Control Cable - Hi-sea

JIS C3410 Collective Screen Control Cable

JIS C3410 Collective Screen Control Cable

JIS C3410 Collective screen control cable application:
This cable is for fixed installation,used in control and signal system in ship.


JIS C3410 Collective screen control cable Applied Standard:
-JISC 3410-1999/2010 -IEC 60092-350 -IEC 60332-1 -IEC 60332-3 Cat.AF(for FA-type)


JIS C3410 Collective screen control cable service condition:
Voltage rating: 250V Maximum conductor temperature:85°C


JIS C3410 Collective screen control cable construction:

Classification Code Construction details
Conductor M Tinned Copper Wire JIS C3410
Insulation P EPR as per JIS C 3410
Common Shield S Tinned Copper Wire
Sheath Y PVC as per JIS C 3410
Armor C Galvanized steel wire braided

CB Tinned copper wire braided
Paint
The white paint should be painted uniformly
Covering Y PVC as per JIS C 3410


Color: Black











Minimum cable bending radius:

The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.

Installations temperature


Minimum recommended temperature of installations:

-10°C Ship wiring cable with PVC sheath

-20°C Elastomeric on/off shore cables


Installations pulling force:

The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.