JIS C3410 Shipboard Telephone Cable - Marine Telecommunication Cable - Hi-sea

JIS C3410 Shipboard Telephone Cable

JIS C3410 Shipboard Telephone Cable

JIS C3410  Shipboard Telephone cable application:
This cable is intended for telephone and instrumentation usage and fixed installation.

JIS C3410 Shipboard Telephone cable standards:
- Design guide : JIS C 3410(1999/2010)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60
JIS C3410 Shipboard Telephone cable Model:
250V TTY, FA-TTY 250V TTYC, FA-TTYC 250V TTYCY, FA-TTYCY
JIS C3410 Shipboard Telephone cable construction:

JIS C3410 Shipboard Telephone cable diagram:

Classification Code Construction details
Conductor TT Tinned Copper Wire JIS C3410
Insulation Y PVC as per JIS C 3410
Armor C Galvanized steel wire braided

CB Tinned copper wire braided
Paint
The white paint should be painted uniformly
Covering Y PVC as per JIS C 3410


Color: Black









Recommendations Minimum cable bending radius:
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations temperature
Minimum recommended temperature of installations:
-10°C Ship wiring cable with PVC sheath
-20°C Elastomeric on/off shore cables
Installations pulling Force:
The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.