MGCH-F Fire Resistant Marine Power Cables - Marine Power Cable - Hi-sea

MGCH-F Fire Resistant Marine Power Cables


MGCH-F Fire Resistant Marine Power Cables

Cable Construction

1.Conductor : Annealed Stranded Bare Copper,Class 2

2.Insulation : Fire Barriers+HEPR(Cross-linked Ethylene Propylene Rubber)

3.Filler or Tape

4.Armour : Separator tape/bare copper braid

5.Sheath : Polyolefin


Standards

International:IEC 60092-353;IEC 60331; IEC 60332-3;IEC 60754-1; IEC 60754-2;IEC 61034

National: DIN 89158/98


Electrical Characteristics

Rated Voltage Uo/U(Um):600/1000V Test Voltage:3500V


Usage Characteristics

Minimum installation temperature:–10°C

Minimum operating temperature: –35°C Short-circuit max.conductor temperature:250 °C

Max.conductor temperature in service:85 °C

Flame Retardant:IEC 60332-3 Cat. A Fire Resistant:IEC 60331

Smoke Density:IEC 61034 Gases Corrosivity:IEC 60754-2

Gases Toxicity:No toxicity to IEC 60754-1

Electric magnetic interference resistance:YES


Minimum Internal Bending Radius

For all cables:6 × cable diameter


Applications

MGCH-F halogen free,fire resistant marine power cables with screen 0.6/1KV are used for cargo ships, Passenger vessels and Special-purpose vessels.

Contact with us now

Our mail: hs@cqhisea.com