YLG-0.12 Vertical Hydrophore Tank - Marine Hydrophore - Hi-sea

YLG-0.12 Vertical Hydrophore Tank

YLG-0.12 Vertical Hydrophore Tank

1. YLG-0.12 Vertical Hydrophore Tank Applicable Range

This pressure water tank is appropriate for the water supply system (fresh water, seawater) on board.

2. YLG-0.12 Vertical Hydrophore Tank Principle Description

The device uses the pressure water pumped by water pump in tank to compress air so as to keep the water in tank under a proper pressure for the use on board.
Liquid level meter: to show the water level condition in tank.
Pressure gauge: to show the pressure in tank.
Pressure controller: to control the start and stop of water pump. When the pressure in tank is under 0.4Mpa, the water pump will start to feed water into tank until the pressure reaches 0.6Mpa.
Safety valve: When the pressure in tank is more than 0.63Mpa, the safety valve will open to release the pressure in tank.
Charge valve: to charge the compressed air into tank.
Discharging valve: to empty the water in tank when maintaining.

3. YLG-0.12 Vertical Hydrophore Tank Main Technical Requirements

Volume:  0.12m3
Working pressure:  0.6MPa
Design pressure:  0.7MPa
Strength test pressure:  1.05MPa
Air tightness test pressure:  0.875MPa
Open pressure of safety valve:  0.63MPa
Working temperature:  0~45℃
Design temperature: 50℃

4. YLG-0.12 Vertical Hydrophore Tank Interface

Model

Water inlet

Water discharging outlet

inflation inlet

Discharging outlet

Safety valve

YLG-0.12

DN25

DN25

DN10

G3/4″

ZG1/2″

5. YLG-0.12 Vertical Hydrophore Tank Gneral Drawing and Base Drawing

6. Quantity be approved by IMO, all kinds class certificate can be supply.