    Cable Application:

    The cable is fixed installation, used for Control, signal system in ship.


    Cable Model:
    250V MPY-S, FA-MPY-S 250V MPYC-S, FA-MPYC-S 250V MPYCY-S, FA-MPYCY-S


    Cable Standards:
    - Design guide : JIS C 3410(1999/2010)

    - Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)

    - Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)

    - Max. conductor temperature :85


    Cable Construction:

    Classification Code Construction details
    Conductor M Tinned Copper Wire JIS C3410
    Insulation P EPR as per JIS C 3410
    Individual Shield -S Tinned Copper Wire
    Sheath Y PVC as per JIS C 3410
    Armor C Galvanized steel wire braided

    CB Tinned copper wire braided
    Paint
    The white paint should be painted uniformly
    Covering Y PVC as per JIS C 3410


    Color: Black













    Recommendations Minimum Cable Bending Radius:

    The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable

    Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.

    Installations Temperature:

    Minimum recommended temperature of installations :

    -10°C Ship wiring cable with PVC sheath

    -20°C Elastomeric on/off shore cables

    Installations Pulling Force:

    The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.