JIS C3410 Individual Screen Control Cable
Cable Application:
The cable is fixed installation, used for Control, signal system in ship.
Cable Model:
250V MPY-S, FA-MPY-S 250V MPYC-S, FA-MPYC-S 250V MPYCY-S, FA-MPYCY-S
Cable Standards:
- Design guide : JIS C 3410(1999/2010)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature :85
Cable Construction:
Classification | Code | Construction details |
Conductor | M | Tinned Copper Wire JIS C3410 |
Insulation | P | EPR as per JIS C 3410 |
Individual Shield | -S | Tinned Copper Wire |
Sheath | Y | PVC as per JIS C 3410 |
Armor | C | Galvanized steel wire braided |
|
CB | Tinned copper wire braided |
Paint |
|
The white paint should be painted uniformly |
Covering | Y | PVC as per JIS C 3410 |
|
|
Color: Black |
Recommendations Minimum Cable Bending Radius:
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable
Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations Temperature:
Minimum recommended temperature of installations :
-10°C Ship wiring cable with PVC sheath
-20°C Elastomeric on/off shore cables
Installations Pulling Force:
The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.