Electromagnetic Controlled Gyrocompass
The Scope of Application:
It is suitable for oceangoing vessels, naval service vessels and other types of vessels.
Product Characteristic:
It is a small type of gyrocompass adopting the technology of electromagnetic control and compensation. The mainly system includes sensor, control and compensation system, azimuth and horizontal follow up system, course transmission system and invertor power. This instrument is compact construction, high accuracy, fast steady and easy operation and maintenance. It can continuously and precisely indicate the ship's heading and determine the azimuth of measured objects.
Product Specification:
life of gyro sphere
|
more than 10000h |
mean time between failures |
more than 2000h |
settle point error |
not exceed ±0.75 º × sec δ |
heading deviation (RMS) |
not exceed 0.25 º × sec δ |
repeatability error of settle point headings |
not exceed 0.25 º × sec δ |
heading error in straight and uniform sailing |
not exceed ±1 º × sec δ |
error due to rapid alteration of speed of 20 knots |
not exceed ±1.5 º |
error due to rapid alteration of course of180º at speed of 20 knots |
not exceed ±2.5 º |
rapid setting time |
less than 2h |
adaptable ship's power supplies |
AC 220V(50HZ) |
the max.difference of reading between the master compass and repeater |
±5 º |
transmission |
torque transmitter,50Hz, (BS404A can be connected) |
weight of the master compass |
less than 35KG |
dimension of master compass |
356 × 286 × 400mm |
dimension of power supply unit |
344 × 474 × 167mm |
dimension of transmission unit |
336 × 466 × 172mm |
Traditional mechanical gyrocompass VS optical fiber compass
Traditional mechanical gyrocompass
The traditional mechanical gyro compass uses the high speed rotation of gyro rotor for north seeking and navigation. High speed rotor stability time is long, easy to heat, wear.
1. Long startup time.
2. High maintenance cost (regular liquid change, ball change, etc.)
3. There are rocking and shock errors. It is not suitable for high speed, high dynamic and high latitude navigation.
4. High volume, power consumption and noise.
5. Inconvenient to carry and install.
Fiber optic compass
The new generation of optical fiber compass is an all-solid state optical and electromechanical integration fiber gyro. It solves the technical problems existing in the traditional mechanical gyrocompass.
1. The comprehensive cost of optical fiber compass is comparable to that of traditional mechanical gyro compass.
2. Low failure rate, small course motion error
Optical fiber compass is maintenance-free.
3. Low power consumption, no noise, small size.
Electromagnetic Controlled Gyrocompass: