YLG-0.12 Vertical Hydrophore Tank
1. YLG-0.12 Vertical Hydrophore Tank Applicable Range
This pressure water tank is appropriate for the water supply system (fresh water, seawater) on board.
2. YLG-0.12 Vertical Hydrophore Tank Principle Description
The device uses the pressure water pumped by water pump in tank to compress air so as to keep the water in tank under a proper pressure for the use on board.
Liquid level meter: to show the water level condition in tank.
Pressure gauge: to show the pressure in tank.
Pressure controller: to control the start and stop of water pump. When the pressure in tank is under 0.4Mpa, the water pump will start to feed water into tank until the pressure reaches 0.6Mpa.
Safety valve: When the pressure in tank is more than 0.63Mpa, the safety valve will open to release the pressure in tank.
Charge valve: to charge the compressed air into tank.
Discharging valve: to empty the water in tank when maintaining.
3. YLG-0.12 Vertical Hydrophore Tank Main Technical Requirements
Volume: 0.12m3
Working pressure: 0.6MPa
Design pressure: 0.7MPa
Strength test pressure: 1.05MPa
Air tightness test pressure: 0.875MPa
Open pressure of safety valve: 0.63MPa
Working temperature: 0~45℃
Design temperature: 50℃
4. YLG-0.12 Vertical Hydrophore Tank Interface
Model |
Water inlet |
Water discharging outlet |
inflation inlet |
Discharging outlet |
Safety valve |
YLG-0.12 |
DN25 |
DN25 |
DN10 |
G3/4″ |
ZG1/2″ |
6. Quantity be approved by IMO, all kinds class certificate can be supply.