• HOME
  • COMPANY
  • PRODUCTS
  • PROJECTS
  • NEWS
  • PRODUCTS
    YLG-0.12 Vertical Hydrophore Tank

    YLG-0.12 Vertical Hydrophore Tank

    1. YLG-0.12 Vertical Hydrophore Tank Applicable Range

    This pressure water tank is appropriate for the water supply system (fresh water, seawater) on board.

    2. YLG-0.12 Vertical Hydrophore Tank Principle Description

    The device uses the pressure water pumped by water pump in tank to compress air so as to keep the water in tank under a proper pressure for the use on board.
    Liquid level meter: to show the water level condition in tank.
    Pressure gauge: to show the pressure in tank.
    Pressure controller: to control the start and stop of water pump. When the pressure in tank is under 0.4Mpa, the water pump will start to feed water into tank until the pressure reaches 0.6Mpa.
    Safety valve: When the pressure in tank is more than 0.63Mpa, the safety valve will open to release the pressure in tank.
    Charge valve: to charge the compressed air into tank.
    Discharging valve: to empty the water in tank when maintaining.

    3. YLG-0.12 Vertical Hydrophore Tank Main Technical Requirements

    Volume:  0.12m3
    Working pressure:  0.6MPa
    Design pressure:  0.7MPa
    Strength test pressure:  1.05MPa
    Air tightness test pressure:  0.875MPa
    Open pressure of safety valve:  0.63MPa
    Working temperature:  0~45℃
    Design temperature: 50℃

    4. YLG-0.12 Vertical Hydrophore Tank Interface

    Model

    Water inlet

    Water discharging outlet

    inflation inlet

    Discharging outlet

    Safety valve

    YLG-0.12

    DN25

    DN25

    DN10

    G3/4″

    ZG1/2″

    5. YLG-0.12 Vertical Hydrophore Tank Gneral Drawing and Base Drawing

    6. Quantity be approved by IMO, all kinds class certificate can be supply.