YLG-3.0 Hydrophore Tank
1. YLG-3.0 Hydrophore Tank Technical Requirements
(1) Flange Standard:CB/T46-1999 PN1.0;
(2) The shell cover thickness including the forming thinning;
(3) The system including security settings;
(4) Pipes and support same as the drawings.
2. YLG-3.0 Hydrophore Tank Outer Joint
Mark |
Name |
Size |
Standard |
a |
relief outlet |
DN32 |
|
b |
Water Inlet |
DN50 |
CB/T46-1999 PN1.0 |
c |
Compressor Air Inlet |
DN10 |
CB*53-80 |
d |
Water Outlet |
DN50 |
CB/T46-1999 PN1.0 |
Working Pressure |
0.6Mpa |
Design Pressure |
0.7Mpa |
Working Temp. |
0~45℃ |
Design Temp. |
50℃ |
Main Materials |
CCS-B/SS304/SS316 |
corrosion allowance |
0.75mm |
welded joint coefficient |
0.6 |
Capacity |
3.0m³ |
The relief valve pressure jump |
0.63MPa |
G.W. |
865 Kgs (with standard export wooden case) |
N.W. |
775 Kgs |
5. Quantity be approved by IMO, all kinds class certificate can be supply.