• HOME
  • COMPANY
  • PRODUCTS
  • PROJECTS
  • NEWS
  • PRODUCTS
    ZYG Series Marine Hydrophore

    ZYG Series Marine Hydrophore

    Introduction

    This series hydrophore is the best water supply unit that is applicable to various types of sea water and fresh water piping water supply combined systems.They have the characteristics of modular unit,compact structure, beautiful shape and easy installation and maintenance.

    Main Products

    ZYG Series Marine Hydrophore


    0.12 m³ ZYG Marine Hydrophore


    0.2 m³ ZYG Pressure Water Tank


    0.3 m³ ZYG Marine Hydrophore Equipment


    0.5 m³ ZYG Hydrophore Tank


    1 m³ ZYG Freshwater Hydrophore Tank


    1.5 ZYG Vertical Hydrophore Tank


    2 m³ ZYG Marine Pressure Water Tank

    ZYG Series Hydrophore Main Technical Parameters


    Model ZYG-
    0.12 0.2 0.3 0.5 1 1.5 2
    Volume(m3) 0.12 0.2 0.3 0.5 1 1.5 2
    Working pressure(MPa) 0.4
    Design pressure (MPa) 0.44
    Test pressure (MPa) 0.66
    Take-off pressure of safety valve(MPa) 0.42
    Working temperature(℃) 0~45
    Design temperature(℃) 50
    Water pump Model 1.5CWX-1.5/1.5A 1.5CWX-2/2A 1.5CWX-3/3A
    Flow rate(m3/h) 3 6.5 10
    Pumping head (m) 40 40 40
    Power(kW) 2.2 3 4
    ZYG Series Hydrophore Basic Dimension

    Model

    Overall Size(mm)

    Base Size(mm)

    Water Inlet

    Water Outlet

    Draining Outlet

    DN

    L

    B

    H

    A

    B

    DN

    ZYG-0.2

    500

    1130

    745

    1635

    1040

    600

    40

    25

    20

    ZYG-0.3

    600

    1170

    742

    1690

    1080

    600

    32

    20

    ZYG-0.5

    700

    1236

    955

    1920

    1160

    700

    32

    20

    ZYG-1.0

    900

    1585

    1216

    2153

    1510

    960

    40

    20

    ZYG-1.5

    1000

    1604

    1310

    2615

    1600

    1000

    40

    20

    ZYG-2.0

    1200

    1812

    1525

    2473

    1810

    1220

    40

    25

    ZYG-2.5

    1200

    1812

    1525

    2873

    1810

    1220

    40

    25

    ZYG Series Hydrophore Principle Description

    The device uses the pressure water pumped by water pump in tank to compress air so as to keep the water in tank under a proper pressure for the use on board.

    1.Liquid level meter: to show the water level condition in tank.

    2.Pressure gauge: to show the pressure in tank.

    3.Pressure controller: to control the start and stop of water pump. When the pressure in tank is under 0.3Mpa, the water pump will start to feed water into tank until the pressure reaches 0.4Mpa.

    4.Safety valve: When the pressure in tank is more than 0.42Mpa, the safety valve will open to release the pressure in tank.

    5.Charge valve: to charge the compressed air into tank.

    6.Discharging valve: to empty the water in tank when maintaining.

    7.Control box: The control box is designed with two control modes, one is manual control, the other one is auto control. It is equipped with main water pump, spare water pump and change-over switch SA3. If select the main water pump, please turn the change-over switch SA3 to “Main”, if select spare water pump, please turn SA3 to “Spare”. When the change-over SA2 is turned to “manual”, the main water pump or spare water pump will be start to work manually. When the change-over switch SA2 is turned to “auto”, the device will enter into auto work. When the high pressure controller detects the pressure in tank has reached 0.4MPa, the main water pump or spare water pump will stop working.


    ZYG Series Hydrophore Maintenance
    (1) Check the tightness of connectors and cocks of suction pipeline so as to avoid the air is sucked in.
    (2) Check the tightness of charge valve
    (3) Check whether the pressure in tank is in control range. If the pressure is too low for a long time, please open the charge valve to fill in appropriate quantity of air.
    (4) Remove and clean the water tank regularly. After cleaning and brushing the inner wall, determine whether repaint according to flaking condition of painting. Repaint the out surface with anti-corrosive paint, meanwhile, replace wearing parts. After the spare parts are dry, reassemble it.
    (5) Speaking of maintenance of water pump, please see the instruction book of water pump.

    Quantity be approved by IMO, all kinds class certificate can be supply.




    Contact with us now
    Name:
    Email:
    Message: