JIS C3410 Armored Control Cable - Marine Control Cable - Hi-sea

JIS C3410 Armored Control Cable

JIS C3410 Armored Control Cable

JIS C3410 Control Cable application:
This product is suitable for all kinds of ships and offshore oil platforms and other control structures and electrical transmission .
JIS C3410 Control Cable Service condition:
Voltage rating: 250V

Maximum conductor temperature: 85°C
JIS C3410 Control Cable Applied Standard:
-JISC 3410-1999 -IEC 60092-350 -IEC 60332-1 -IEC 60332-3 Cat.AF(for FA-type)
JIS C3410 Control Cable Construction:

Conductor M Tinned annealed stranded copper, class 2 according to IEC 60228
Insulation P 85°C EPR as per JIS C 3401
Cabling
Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used
Bedding Y PVC as per JIS C 3401
Armor C Galvanized steel wire braid
Sheath Y PVC as per JIS C 3401
Core identification
Black No. on white insulation /Black No. on white insulation, G/Y
Outer sheath color
Black










Minimum cable bending radius:

The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable

Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.

Installations temperature:

Minimum recommended temperature of installations :

-10°C Ship wiring cable with PVC sheath

-20°C Elastomeric on/off shore cables

Installations pulling force:

The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.

Additional tension will be supplied from the braid and the insulation and sheathing compound.

JIS C3410 Control Cable Parameter:

<
No. of cores Conductor Thick. of insulation Thick. of bedding (FA-) MPY
Size Construction O.D Nom. overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm kg/km
2 1 7/0.43 1.29 0.7 1.1 8.7 0.4 85
4 1 7/0.43 1.29 0.7 1.1 9.9 0.4 125
7 1 7/0.43 1.29 0.7 1.2 11.9 0.5 190
12 1 7/0.43 1.29 0.7 1.3 15.5 0.7 315
19 1 7/0.43 1.29 0.7 1.4 18.3 0.8 465
27 1 7/0.43 1.29 0.7 1.6 22.1 0.9 665
37 1 7/0.43 1.29 0.7 1.7 24.8 1 870
44 1 7/0.43 1.29 0.7 1.8 28 1.2 1160
77 1 7/0.43 1.29 0.7 2.1 35.9 1.5 1790
<
No. of cores Conductor Thick. of insulation Thick. of bedding Dia. of steel wire Thick. of covering (FA-) MPYCY
Size Construction O.D Nom. overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm mm mm kg/km
2 1 7/0.43 1.29 0.7 1.1 0.3 0.9 12 0.5 205
4 1 7/0.43 1.29 0.7 1.1 0.3 0.9 13.2 0.5 260
7 1 7/0.43 1.29 0.7 1.2 0.3 0.9 15.2 0.6 350
12 1 7/0.43 1.29 0.7 1.3 0.3 1 19 0.8 530
19 1 7/0.43 1.29 0.7 1.4 0.3 1.1 22 0.9 720
27 1 7/0.43 1.29 0.7 1.6 0.3 1.2 26 1 980
37 1 7/0.43 1.29 0.7 1.7 0.3 1.3 28.9 1.2 1240
44 1 7/0.43 1.29 0.7 1.8 0.3 1.3 32.1 1.3 1470
77 1 7/0.43 1.29 0.7 2.1 0.4 1.5 41.1 1.6 2470

Contact with us now

Our mail: hs@cqhisea.com

replace