Marine Oil and Water Separator - Marine Oil Water Separator - Hi-sea

Marine Oil and Water Separator

Marine Oil and Water Separator

1. Marine Oil and Water Separator Application

This device can be used to treat the oily bilge water in order to make it reach the requirements of IMO.MEPC.107 (49) resolution, which is also called 15ppm bilge separator. It contains type approved 15ppm bilge water separator, 15ppm bilge alarm and automatic shut down device.

2. Marine Oil and Water Separator Installation

(1) Base of the device

All the components of the device are installed on the equipment base welded by channel steel. A ship base which matches the size of the bottom of the equipment base should be fixed in the machine cabin. The ship base should be welded with the ship structure. The ship base is connected to the bottom of the base of device by bolts and channel special square bevel gaskets GB/T853 suggested. See attached Figure 2, the size of the device base and the position of connecting bolt holes.

(2) Connection of the pipes

The bilge suction, effluent discharge, back flushing water inlet, and Return to bilge interface, oil outlet. should be fitted by the shipyard.

Name

Type

Oil water inlet

Discharge liquit outlet

Clean water inlet

Return to bilge interface

Oil outlet

Return to bilge interface

Concentrated liquid Return to bilge interface

YWC-0.25

DN20

DN20

DN20

DN20

DN20

DN20

None

YWC-0.50

DN25

DN25

DN25

DN25

DN25

DN25

YWC-1.00

DN25

DN25

DN25

DN25

DN25

DN25

YWC-1.50

DN25

DN25

DN25

DN25

DN25

DN25

YWC-2.00

DN32

DN32

DN32

DN32

DN32

DN32

YWC-2.50

DN32

DN32

DN32

DN32

DN32

DN32

YWC-3.00

DN32

DN32

DN32

DN32

DN32

DN32

DN32

YWC-4.00

DN50

DN50

DN50

DN50

DN50

DN50

DN32

YWC-5.00

DN50

DN50

DN50

DN50

DN50

DN50

DN32

(3) Connection of electric box

Power source 380V/440V, 3Ф, 50HZ/60HZ is connected into electric control box; Bilge level probe, refer to electric draw, when the product leaves from the factory, the external contact points JYB3 #15, #5 or #6 of the liquid level relay which is used to detect the bilge water level are short connected. If bilge level probe needed to be linked, the short connected copper wire should be removed.

3. Warning of Marine Oil and Water Separator

The operator should skill a basic technology and be familiar with the instruction. Also he should master the operation control and know clearly the maintenance regulations.

4. Certificates of Marine Oil and Water Separator: CCS, EC, BV, GL , KR, DNV, LR, ABS, RINA approvable.