SIOI SICI Fire Resistant Shipboard Instrumentation Cable
This SIOI SICI cable is designed for telephone & instrument circuits up to 150/250V.Suitable for use in commercial marine applications.
SIOI SICI fire resistant Shipboard instrumentation cable Standards
Design Guide : IEC 60092-350, 376
Insulation Material : IEC 60092-351
Sheath Material : IEC 60092-359
Flammability : IEC 60332-1 & IEC 60332-3 Category A
Fire Resistance : IEC 60331 (750℃or 1000℃)
Halogen Content : IEC 60754-1,2, 0.5%(Max.)
Smoke Emission : IEC 61034-1,2, 60%(Min.)
SIOI SICI fire resistant Shipboard instrumentation cable construction
Classification | Code Letter | Construction Detail |
Conductor |
|
Plain (or Tinned), Annealed, Stranded copper wire |
Fire Resisting Layer | S | Mica / Glass Tape (MGT) |
Insulation | Cross-linked Polyethylene (XLPE) as per IEC 60092-351 | |
Inner Sheath | I | Halogen Free Thermoplastic compound (SHF1) as per IEC 60092-359 |
Armor | C or O |
Galvanized Steel Wire Braid (C) Copper Wire Braid (O) |
Outer Sheath | I |
Halogen Free Thermoplastic compound (IEC 60092-359, SHF1) Sheath color - Non-intrinsically safe cable : Black - Intrinsically safe cable : Blue |
Core Identification |
|
1) Each pair/triad - Pairs : Black, White - Triads : Black, White, Red 2) Multi pair/triad cables Multi pair/triads are identified by lapping of the pair/triad numbered tape or by the pair/triad number print directly on the each cores. 3) The other color scheme may be applicable when purchaser required. |
Fire resistance cable to IEC 60331 (at 1000℃) can be supplied if required.
SIOI SICI fire resistant Shipboard instrumentation cable Specification
Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)
1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)
Size (sqmm): 0.75, 1, 1.5, 2.5