Explosion Proof Fire Damper
1. Features:
Our fire damper are especially designed for sea environment, and widely used for navy vessels, off-shore platform and underground projects etc. The fire damper could effectively hinder hydrosphere and fog in duct, and work well in this environment.
2. Main technical parameter:
Iterm Types |
Manual fire damper |
Electrical fire damper |
Pneumatic fire damper |
Fusing temp. |
70±3℃ |
70±3℃ |
70±3℃ |
Closed time |
<2s |
<1s |
<2s |
Air leakage ate |
≤5m³/m².h |
≤5m³/m².h |
≤5m³/m².h |
Air source pressure |
--- |
--- |
Compressed air of 0.5~0.8MPa |
Control voltage |
--- |
DC24V/AC110V/AC220V |
|
Protection degree |
--- |
IP44/IP56/IP65/IP67 |
|
Explosion-proof degree |
--- |
ExdⅡBT~BT6 ExdⅡCT4~CT6 |
Features
Control mechanism
Electric
It can be manually operated on-site and can be controlled remotely.
Pneumatic
It can be manually operated on-site and can be controlled remotely. Pneumatic fire dampers are generally installed in hazardous areas.
Shape
Round/Rectangle
Explosion-proof requirements
Explosion-proof
For use in hazardous areas, containing explosive gases
Control Voltage
DC24V/AC110V/AC220V
Protection Degree
IP44/IP56/IP65/IP67
Explosion-proof Degree
ExdIIBT4~BT6 ExdIIC4~CT6
4. Specific Difference Between Us and Other Suppliers:
Comparison
Product Picture of other low quality supplier
Product Picture of our factory
Other low quality supplier
Consequence
Our Factory
Consequence
Air leakage does not meet the requirements
Excessive air leakage from fire dampers will cause major safety hazards
Airtight performance is selected according to requirements
The air leakage meets the requirements, and the product is safer to use
The installation accuracy of the connecting rod between the baffles is not enough
As a result, when the fire damper is closed, the shutter still cannot be completely closed.
The connecting rod between the baffles is installed with high precision
When the fire damper is closed, the shutter can be fully closed.
The fire rating does not meet the requirements
It is easy to leave a safety hazard
Select as required
Product use more assured, longer service life
The thickness of the damper shell does not meet the requirements
The casing is prone to breakage
The thickness selection of the damper shell The regulations of each classification society are consistent with the SLOAS requirements
The shell meets the requirements, and the damper can be used for a longer time
5.Our Inventory:
6. IACS Certificate: KR, DNV▪GL, CCS, ABS, CE, LR, BV