    HVAC System Fire Damper

    HVAC System Fire Damper

    Features
    The fire damper used for resisting fire in HVAC duct system. The fire damper could be shut off automatically at once to prevent the fire spreading along air duct when it fired and the temperature in air duct got to more than 70℃.
    Our fire damper are especially designed for sea environment, and widely used for navy vessels, off-shore platform and underground projects etc. The fire damper could effectively hinder hydrosphere and fog in duct, and work well in this environment.

    Configuration Options:

    Features

    Control Mechanism

    Manual

    On-site manual operation

    Electric

    It can be manually operated on-site and can be controlled remotely.

    Pneumatic

    It can be manually operated on-site and can be controlled remotely. Pneumatic fire dampers are generally installed in hazardous areas.

    Shape

    Round

    User specified

    Rectangle

    User specified

    Explosion-proof Requirements

    Explosion-proof

    For use in hazardous areas, containing explosive gases

    Non-explosion proof

    It is installed on the air duct of the ventilation and air-conditioning system with fire protection requirements.

    Protection Degree

    IP44/IP56/IP65/IP67

    User specified

    Explosion-proof Degree

    Exd II BT4~BT6

    Exd II CT4~CT6

    User specified

    Material

    Carbon steel

    Higher hardness and better wear resistance can be obtained after heat treatment. The hardness in the annealed state is very moderate, and it also has good machinability. Raw materials are very common, simple and easy to obtain, and the production cost is relatively low.

    Stainless steel

    It has good plasticity, toughness, weldability, corrosion resistance and non-magnetic properties, and has good corrosion resistance in oxidizing and reducing media.

    Specific Difference Between Us and Other Suppliers

    Comparison

    Product Picture of other low quality supplier


    Product Picture of our factory


    Other low quality supplier

    Consequence

    Our Factory

    Consequence

    The installation accuracy of the connecting rod between the baffles is not enough

    As a result, when the fire damper is closed, the shutter still cannot be completely closed.

    The connecting rod between the baffles is installed with high precision

    When the fire damper is closed, the shutter can be fully closed.

    The thickness of the damper shell does not meet the requirements

    The casing is prone to breakage

    The thickness selection of the damper shell The regulations of each classification society are consistent with the SLOAS requirements

    The shell meets the requirements, and the damper can be used for a longer time

    The fire rating does not meet the requirements

    It is easy to leave a safety hazard

    Select as required

    Product use more assured, longer service life

    Air leakage does not meet the requirements

    Excessive air leakage from fire dampers will cause major safety hazards

    Airtight performance is selected according to requirements

    The air leakage meets the requirements, and the product is safer to use

    Main technical parameter

    Iterm

    Types

    Manual fire damper

    Electrical fire damper

    Pneumatic fire damper

    Fusing temp.

    70±3

    70±3

    70±3

    Closed time

    2s

    1s

    2s

    Air leakage ate

    5m³/m².h

    5m³/m².h

    5m³/m².h

    Air source pressure

    ---

    ---

    Compressed air of

    0.5~0.8MPa

    Control voltage

    ---

    DC24V/AC110V/AC220V

    Protection degree

    ---

    IP44/IP56/IP65/IP67

    Explosion-proof degree

    ---

    ExdBT~BT6 ExdCT4~CT6

    Picture in the factory

    Maintenance:
    1. Regularly test all the air locks and air lock shutters of the whole ship every week, manually switch it several times, check whether the signal output is consistent with the working state of the sausage, and make corresponding records;
    2. Regularly and quantitatively apply some lubricating oil to the blades of the damper shutters;
    3. Check the action of the two-position three-way solenoid valve on site at least once a week.
    IACS Certificate: LR, CE, ABS, DNV•GL, KR, BV, CCS