Application:
This Cable can be applied in Marine&Offshore and various ships, ship repair and oil platforms and other offshore buildings control device and general electric lighting,machinery and equipment of factories and mines are also equally applicable.
Standards:
JISC 3410-1999/2010 IEC 60332-1 IEC 60332-3 Cat.A(for FA-type)
Model:
[FA-] SPYCS, SPYCBS, DPYCS, TPYCS, FPYCS [FA-] SPYCYS, SPYCBYS, DPYCYS, TPYCYS, FPYCYS 0.6/1kV SPYCBS, FA- SPYCBS 0.6/1kV SPYCBYS, FA- SPYCBYS 0.6/1kV DPYS, TPYS, FA-DPYS, FA-TPYS 0.6/1kV DPYCS, TPYCS, FA-DPYCS, FA-TPYCS 0.6/1kV DPYCYS, TPYCYS, FA-DPYCYS, FA-TPYCYS
Structure:
Diagram:
Conductor | S(D,T) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
Conductor screen | Semi-conducting compound | |
Insulation | P | 85°C EPR as per IEC 60092-351 |
Cabling | Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used | |
Overall shield | S | Tinned copper wire braid |
Bedding | Y | PVC as per JIS C 3401 |
Armor | C (CB) | Galvanized steel wire braid(-C TYPE) or copper alloy wire braid(-CB TYPE) |
Sheath | Y | PVC as per JIS C 3401 |
Core identification | 1C Black 2C Black, White 3C Black, White, Red | |
Outer sheath color | Black |
Installations recommendations:
Minimum cable bending radius
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than : 6 times the external diameter of cable Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations temperature
Minimum recommended temperature of installations : -10°C Ship wiring cable with PVC sheath -20°C Elastomeric on/off shore cables Installations pulling force The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.