FA-DPYC Shipboard Power Cable
Application:
For fixed installations on ships and offshore-units in all locations.
FA-DPYC 0.6/1KV:
Flame-Retardant,Double core,EP rubber insulated,PVC sheathed,Steel wire braid Shipboard Power cable.
Cable Construction:
1.Conductor:Stranded tinned annealed copper wires as per JIS C 3410.
2.Insulation:(EPR),Ethylene Propylene Rubber.
3.Cabling:Flame retardant and non-hygroscopic fillers may be used.Suitable tape may be applied on the cabled core.
4.Sheath:(PVC),Polyvinyl Chloride.
5.Armor:Galvanized steel wire braid.Coverage density is minimum 90%.
6.Paint:The white paint shall be painted uniformly on the steel wire braid.
7.Core identification:2 Core:Black,White
Standard:
Design:JIS C 3410:2010 Flame retardant:IEC 60332-1 & IEC 60332-3 Category A(FA-Type)
Conductor | S(D,T) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
Conductor screen |
|
Semi-conducting compound |
Insulation | P | 85°C EPR as per IEC 60092-351 |
Cabling |
|
Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used |
Overall shield | S | Tinned copper wire braid |
Bedding | Y | PVC as per JIS C 3401 |
Armor | C (CB) | Galvanized steel wire braid(-C TYPE) or copper alloy wire braid(-CB TYPE) |
Sheath | Y | PVC as per JIS C 3401 |
Core identification |
|
1C Black 2C Black, White 3C Black, White, Red |
Outer sheath color |
|
Black |