50 Persons Biochemical Sewage Treatment Plant
Brief Introduction of 50 Persons Biochemical Sewage Treatment Plant
50 persons marine biochemical sewage treatment plant adopts the method of combining catalytic oxidation, the MBR membrane biological treatment and physical disinfection sterilization ; it treats the domestic sewage of kitchens, W.C., and base room from ship. Since filler is set in the aeration chamber, the chlorine adding sterilization is adopted.
Drawing & Specification
No.
Parts
Material
1
Base
8#steel
2
Crushing discharge pump
Assembly
3
Crushing pump outlet piping
Assembly
4
Cork
brass
5
vacuum pump
Assembly
6
vacuum pump outlet pipe
Assembly
7
Electric control box
Assembly
8
Nameplate
316L
9
Notification
316L
10
UV electric control box
Assembly
11
UV
Assembly
12
Sediment tank pipes
Assembly
13
Handhole cover plate
Q235-B
14
Liquid level electrode
Assembly
15
Gasket
rubber
16
Observation window
organic glass
17
Observation cover plate
Q235-B
18
M8*40 Bolts
Q235-B
19
Washer
Q235-B
20
Membrane tank cover palte
Q235-B
21
M10*40 Bolts
Q235-B
22
M10 nut
Q235-B
23
Washer
Q235-B
24
Crushing pump inlet pipe group
20#
25
vacuum pump inlet
26
Tank
27
Cover plate
Q235-B
28
Aeration pipe
29
Air pump
30
Sludge return pipe
31
Doing Equipment
Marine Black Water Treatment Plant
Load
Average load
3780
(L/d)
Peak load
473
(L/h)
Organic load
1.89
(kgBOD5/d)
50
Max capacity(men)
54
Electricity
AC 380V/50Hz/3φ, AC 415V/50Hz/3φ, AC 440, 60Hz/3φ, etc.
Power (kW)
3
Weight
Dry weight(kg)
1450
Wet weight(kg)
5073
Effluent standard
BOD5≤25 Qi/Qe mg/L, COD≤125Qi/Qe mg/L, TSS≤35 Qi/Qe mg/L, coliform≤100/100ml, PH6~8.5, CL2≤0.5mg/L
IACS Certificate Options: BV, CCS, NK, DNV, GL, IRS, ABS, LR, RMRS, RINA