CJ86 VFD Armored Marine Power and Control Cable
Applications
This product is used in ships,petrol platforms and offshore buildings for power,light and control systems,usually used for fixed installation in most areas and open deck in ships.Design to meet requirements for Variable Frequency Drivers (VFD).If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.
Constructions
1.Conductor
Stranded copper wire Class 5(Flexible)
2.Insulation
XLPE
3.Bedding
Separate tape
4.Screen
Copper tape,covering 100%
5. Amore
Copper wire braided,covering 90% Tinned copper wire on request
6.Sheath
Thermoplastic Polyolefine(SHF1),On requesting Thermosetting Polyolefine(SHF2)
Standard colour black, other colours on request.
Applied Standards
Design | IEC 60092-353 |
Conductor | IEC 60228 Class 5 |
Insulation | IEC 60092-351 |
Armor | IEC 60092-350 |
Sheath | IEC 60092-359 |
Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
Halogen-free | IEC 60754 series |
Smoke emission | IEC 61034 series |
Transfer Impedance | IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) |
Service Conditions
1.Rated Voltage:1,8/3kV (3,6kV)
2.long time working temperature 90℃
3.Minimum recommended installation temperature -15 °C
Lowest operation temperature -40 °C
4.flexible cables for mobile devices,the other cables are fixed laying cable bending radius while laying is as below
Cable Structure | Cable Outer Diameter | Minimum Bending Radius |
Metal Braided Armored | 6D | |
Non Armored | D≤25 | 4D |
D>25 |
6D |