YWC Series 15ppm Bilge Water Separator
Application
This device can be used to treat the oily bilge water in order to reach the requirements of IMO.MEPC.107 (49) resolution, which is also called 15ppm bilge separator. It contains type approved 15ppm bilge water separator, 15ppm bilge alarm and Automatic shut down Device.
Main Products
YWC Series 15ppm Bilge Water Separator | |||
|
|
|
|
|
|
|
|
|
No. |
Name |
Qty. |
1 |
Body |
1set |
2 |
Coalescer |
1set |
3 |
Filter |
1set |
4 |
Membrane |
1set |
5 |
Electric control box |
1set |
6 |
Oil content meter |
1set |
7 |
plunger pump |
1set |
8 |
Pneumatic valve |
3psc |
9 |
Pneumatic three-way valve |
2pcs |
10 |
Air/ electric change over solenoid valve |
7pcs |
11 |
Spring flow meter |
1pcs |
12 |
Dosing pump |
1set |
13 |
Safety valve |
1pcs |
14 |
Differential pressure gauge |
2pcs |
15 |
Thermometer |
1pcs |
16 |
Pressure gauge |
1pcs |
17 |
Piping accessory of device |
1set |
18 |
bottom valve |
1pcs |
19 |
Level controller |
1pcs |
Filter
Brand |
Foreign Famous Brand |
Domestic Brands |
Pro & Cons |
It has a strong filtration performance and long service life, but the price is high. |
The price is lower, but the filtration performance is average, the service life is short, and it needs to be replaced frequently. |
Membrane
Brand |
Foreign Famous Brand |
Domestic Brands |
Pro & Cons |
It has a strong filtration performance and long service life, but the price is high |
The price is lower, but the filtration performance is average, the service life is short, and it needs to be replaced frequently. |
Piston pump
Brand |
Foreign Famous Brand |
Domestic Brands |
Pro & Cons |
It has a long service life and stable operation with high overall efficiency. |
The pump body is reletive fragile, and the service life is shorter, easy to brake. The work process is unstable. |
Spare parts list
No.
Name
Quantity
1
Oil seal of piston pump
2pcs
2
The 2nd stage fiber filter
pcs
3
Sealing strip of coalescer
1pcs
4
O-ring of filter
1pcs
5
O-ring of flange
8pcs
Specifications
Rated Capacity
(m3/h)
1000
×
600
×
1250
1100
×
690
×
1460
1050
×
1000
×
1620
1100
×
1130
×
1650
1900
×
1120
×
1700
1900
×
1120
×
1900
1700
×
1500
×
1900
2280
×
1700
×
1900
2590
×
2000
×
1900
Weight
(kg)
Applicable Vessel
(KDWT)
Working Principle
Model
YWC-
0.25
0.5
1
1.5
2
2.5
3
4
5
Technical Specifications
0.25
0.5
1
1.5
2
2.5
3
4
5
≤15ppm
Discharged Water Oil Content
1
3
6
6
6
6
6
12
12
Electric Heater Power (KW)
0.37
0.55
0.75
1.1
1.1k
1.5kw
1.5kw
2.2kw
2.2kw
Electric Motor Power (KW)
AC 380V/50Hz/3φ, AC 415V/50Hz/3φ, AC 440/60Hz/3φ, AC 480V/60HZ/3φ, etc.
Electrical System
≤6m (H2O)
Suction Head
5-10m (H2O)
Discharged Water Pressure
1000×600
1100×690
1050×1000
1100×1130
1900×1120
1900×1120
1700×1500
2280×1700
2590×2000
Outline Dimension (mm)(L×W×H)
Base
5#
6#
6#
6#
8#
8#
8#
10#
10#
Dry Weight
400
600
800
1060
1260
1500
1800
2100
2500
Wet Weight
550
900
1200
1650
2260
2800
3200
3900
4600
Dry Weight
400
600
800
1060
1260
1500
1800
2100
2500
<1
1-5
5-10
10-30
30-50
50-100
100-200
100-300
>300
The device adopts the combination of 1st stage cone plate gravity and coalesce separator; 2nd stage fiber filter, and 3rd stage membrane permeation, in order to make the treated bilge water to reach the requirements of discharge standard of the Resolution of IMO MEPC.107 (49).
bilge water comes into the 1st stage separator, inside it is a vacuum negative pressure stage by the suction of the feeding pump, and it effectively prevents the problem that the bilge water is difficult to be separated because of the emulsion caused by feed pump under pressure. The liquid coming out of Feeding pump is adsorbed and filtered by the 2nd stage fiber filter, and then goes into the 3rd stage membrane to reach the discharge standard.
Maintenance
1 Daily maintenance
1.1 The suction filter assembly must be washed at least once for each week. If the strainer mesh is damaged, it should be timely repaired or replaced with 80 stainless steel wire mesh.
1.2 Inspect the operating state of the bilge water pump, such as the operating temperature, noise, leakage and the belt tension etc.
1.3 Regularly inspect and record the working pressure of the manometers. Whether the equipment is operating normally or not may be decided by the pressure differences of the coalescer and dialysis apparatus .
1.4 Inspect the operating state of the automatic oil-discharging device.
1.5 Inspect he operating state of the 15ppm bilge water alarm device according to the Operating Instructions for the 15ppm Bilge Water Alarm Device.