    CLLS Marine Water Cooled Water Chilling Unit


    CLLS Marine Water Cooled Water Chilling Unit


    Overview

    CLLS marine water chilling unit mainly consists of refrigeration compressor, marine high-efficient condenser,liquid supply solenoid valve, dry-type evaporator, electrical control cabinet, instrument and valves,etc.

    All components of this unit are already assembled by the manufacturer; also pressure test and vacuum test for cooling system are already done. Sufficient amount of R404A gas is filled in.


    Installation in Shipyard

    1. Pay attention not to damage any component of the tube system and the unit during lifting. The body is made of thin steel plates, hangers shall be used for lifting. Wooden plate shall be used as protection pad for wall face in order to protect the body from damage.

    2. See General Drawing or Overall Dimension Drawing for the dimension of bolt hole in the base of water chilling unit.

    3. Shock insulation measures shall be considered at the base of water chilling unit.

    4. Crelative valves and thermometer necessary for water inlet and outlet pipes of condenser shall be installed by shipyard, while water pressure gauge and water pressure controller have been properly installed by the manufacturer.

    5. Connect feed cable conductor to the power line terminals in the electrical control cabinet, and lay the alarm wire, etc.


    Main Technical Parameter

    CLLS-100 CLLS-130 CLLS-150 CLLS-250 CLLS-300
    Cooling Capacity 116 151 175 290 340
    Compressor Motor Power 32 37 39 75 90
    Fresh Water Flow 20 35 30 50 60
    Cooling Water Flow 32 37 39 75 90
    Cooling Water Press Drop ≤70 ≤70 ≤70 ≤70 ≤70
    Fresh Water Temp 12℃(water in/7℃(water out
    Cooling Water Medium ≤32℃(Sea Water/≤36℃(Fresh Water
    Protection HV,LV,Oil Pressure,Water Pressure,Fresh Water Flow,Overload,Safety Valve,Power Supply Faults
    Power AC380V 3Ph 50Hz   /  AC440V 3Ph 60Hz
    Regeneration Medium R22 ( R134AR404A R407C )
    Adjustable Range 0-25 -50 -75 -100
    Weight ~1200 ~1500 ~1700 ~2000 ~2500

    CLLS-220S CLLS-260S CLLS-330S CLLS-440S CLLS-530S
    Cooling Capacity 256 302 383 512 616
    Compressor Motor Power 64 74 78 114 150
    Fresh Water Flow 44 52 66 83 106
    Cooling Water Flow 64 74 78 114 150
    Cooling Water Press Drop ≤70 ≤70 ≤70 ≤70 ≤70
    Fresh Water Temp 12℃(water in/7℃(water out
    Cooling Water Medium ≤32℃(Sea Water/≤36℃(Fresh Water
    Protection HV,LV,Oil Pressure,Water Pressure,Fresh Water Flow,Overload,Safety Valve,Power Supply Faults
    Power AC380V 3Ph 50Hz    /   AC440V 3Ph 60Hz
    Regeneration Medium R22 ( R134AR404AR407C )
    Adjustable Range 0-25 -50 -75 -100
    Weight ~2100 ~2400 ~2600 ~3300 ~3800