CLN Marine Condensing Unit
Overview
CLN Marine condensing units are provide refrigerant liquid for direct end device of air conditioning system. The unit has features of new-design、easy-operation、stable-working、safety and convenient-maintaining etc. They are widely applied for all kinds of passenger ships、cargo ships and oil platforms etc..
Main Technical Parameter
CLN-23 | CLN-35 | CLN-46 | CLN-58 | CLN-70 | CLN-82 | |||
Cooling Capacity | kW | 23 | 35 | 46 | 58 | 70 | 82 | |
Cooling medium | R22 ( R134A, R404A, R407C ) | |||||||
Power supply | Main circuit | AC380V 3φ 50Hz/AC 440V 3φ 60Hz | ||||||
Control circuit | AC220V 1φ 50Hz/AC 220V 1φ 60Hz | |||||||
Protection devices |
HIgh pressure, low pressure, ( oil pressure ), water stop, lack phase, overload and safety valve |
|||||||
Compressor | Type | hermetic or semi-hermetic compressor | ||||||
Energy reulation | % | / | 0,50,100 ( 0,66,100 ) | |||||
Motor power | kW | 6 | 9 | 11 | 16 | 19 | 22 | |
Condenser | Type | horizontal shell & tube | ||||||
Water inlet temp | ℃ | ≤36 | ||||||
Motor power | kW | 7 | 10 | 13.5 | 17 | 20 | 23 | |
Water preesure loss |
kPa | ≤50 | ≤70 | |||||
Weight | kg | ~680 | ~900 | ~1000 | ~1000 | ~1100 | ~1200 |
CLN-93 | CLN-105 | CLN-116 | CLN-140 | CLN-151 | CLN-175 | |||
Cooling Capacity | kW | 93 | 105 | 116 | 140 | 151 | 175 | |
Cooling medium | R22 ( R134A, R404A, R407C ) | |||||||
Power supply | Main circuit | AC380V 3φ 50Hz/AC 440V 3φ 60Hz | ||||||
Control circuit | AC220V 1φ 50Hz/AC 220V 1φ 60Hz | |||||||
Protection devices |
HIgh pressure, low pressure, ( oil pressure ), water stop, lack phase, overload and safety valve |
|||||||
Compressor | Type | hermetic or semi-hermetic compressor | ||||||
Energy reulation | % | 0,50,100( 0,66,100 ) | ||||||
Motor power | kW | 24 | 26 | 30 | 37 | 2x22 | 2x24 | |
Condenser | Type | horizontal shell & tube | ||||||
Water inlet temp | ℃ | ≤36 | ||||||
Motor power | kW | 27 | 30 | 35 | 40 | 45 | 50 | |
Water preesure loss |
kPa | ≤80 | ||||||
Weight | kg | ~1300 | ~1350 | ~1450 | ~1580 | ~1850 | ~1950 |
CLN-186 | CLN-198 | CLN-230 | CLN-256 | CLN-267 | CLN-302 | |||
Cooling Capacity | kW | 186 | 198 | 230 | 256 | 267 | 302 | |
Cooling medium | R22 ( R134A, R404A, R407C ) | |||||||
Power supply | Main circuit | AC380V 3φ 50Hz/AC 440V 3φ 60Hz | ||||||
Control circuit | AC220V 1φ 50Hz/AC 220V 1φ 60Hz | |||||||
Protection devices |
HIgh pressure, low pressure, ( oil pressure ), water stop, lack phase, overload and safety valve |
|||||||
Compressor | Type | hermetic or semi-hermetic compressor | ||||||
Energy reulation | % | 0,50,75,100( 0,50,66,100 ) | ||||||
Motor power | kW | 2x24 | 2x26 | 2x30 | 2x33 | 2x37 | 2x40.5 | |
Condenser | Type | horizontal shell & tube | ||||||
Water inlet temp | ℃ | ≤36 | ||||||
Motor power | kW | 52 | 55 | 65 | 72 | 80 | 95 | |
Water preesure loss |
kPa | ≤80 | ||||||
Weight | kg | ~2100 | ~2150 | ~2200 | ~2250 | ~2550 | ~2750 |