HUC LUC Marine Air Cooler Unit
Overview
HUC、LUC marine unit cooler is freon direct evaporating coli with fin. It forces air circulation to cool goods. Thus is the features of little freon charging capacity, high cooling efficiency, quick lowing temperature, uniform room temperature, compact structure, small volume, light weight, convenient installing and maintaining etc. CGL、CDL marine low temperature unit cooler is used for the refrigerating room that the room temperature is over 0℃ and for storing non freeze resistance food and cooked food such as: vegetable melons and fruits, dairy products, bean products, eggs etc. It is widely used for food refrigerating room . CGL、CDL marine low temperature unit cooler is used for refrigerating room that room temperature is lower than 0℃. It is used for storing meat, fish or birds etc, and for refrigerating ice cabinet , ice-cream brick , medicine and chemical reagent, import and export transporting foods etc.
Main Technical Parameters
Main Technical Parameters of High Temperature Unit Cooler
Type | HUC-8 | HUC-13 | HUC-20 | HUC-25 | ||
Cooling capacity | kw | 2.09 | 2.91 | 4.65 | 5.58 | |
Room temperature/ evaporature temperature |
℃ | +1~5℃/-9~5℃ | ||||
Cooling medium | R22 ( R134A, R404A, R407C ) | |||||
Freon charged capacity | kg | 0.9 | 1.5 | 2.5 | 3 | |
Connection pipe |
Liauid inlet pipe |
mm | φ12 x 1 | |||
Air return pipe |
mm | φ19 x 1.5 | φ19 x 1.5 | φ19 x 1.5 | φ22 x 1.5 | |
Drain pipe | mm | G1'' | ||||
Evaporating type |
Copper tube aluminium fin with repellent copper coating or copper tube copper fin |
|||||
Fan | type | set | Horizontal axil x 1 | Horizontal axil x 1 | Horizontal axil x 2 | Horizontal axil x 2 |
Air flow | m3/h | 1000 | 1700 | 1000x2 | 1700x2 | |
Total air pressure |
Pa | 170 | ||||
Matched motor |
Power supply | AC380V 3φ 50Hz/AC440V 3φ 60Hz | ||||
type | Marine hermetic | |||||
Power | W | 90 | 105 | 2x90 | 2x115 | |
Dimension length x width x height |
730x425x490 | 730x425x490 | 1130x425x490 | 1130x425x490 | ||
Weight | kg | ~35 | ~65 | ~120 | ~130 |
Main Technical Parameters of low Temperature Unit Cooler
Type | LUC-6 | LUC-10 | LUC-15 | LUC-20 | LUC-25 | ||
Cooling capacity | kW | 1.05 | 1.74 | 2.59 | 3.94 | 4.65 | |
Room temperature/ evaporature temperature |
℃ | -15~25/-25~35 | |||||
Cooling medium | R22 ( R134A, R404A, R407C ) | ||||||
Connection pipe |
Liauid inlet pipe |
mm | DN10 | ||||
Air return pipe |
mm | φ19 x 1.5 | φ19 x 1.5 | φ22 x 1.5 | φ22 x 1.5 | φ22 x 1.5 | |
Drain pipe | mm | G'' | |||||
Evaporating type |
Copper tube aluminium fin with repellent copper coating or copper tube copper fin |
||||||
Fan | type | set | Horizontal axil x 1 | Horizontal axil x 1 | Horizontal axil x 2 | Horizontal axil x 2 | Horizontal axil x 2 |
Air flow | m3/h | 1000 | 1700 | 100x2 | 1000x2 | 1000x2 | |
Total air pressure |
Pa | 170 | |||||
Matched motor |
Power supply | AC380V 3φ 50Hz/AC440V 3φ 60Hz | |||||
type | Marine hermetic | ||||||
Power | W | 80 | 90 | 2x90 | 2x105 | 2x145 | |
Speed | r/m | 2900 | |||||
AC220V Defrost electric heater |
Installing part |
Coil | 5x200 | 5x350 | 5x550 | 5x600 | 5x600 |
Drip pan | 200 | 350 | 500 | 600 | 600 | ||
Drain pipe | 160 | ||||||
insulating resistance |
Cold state | >50 | |||||
Hot state | >0.5 | ||||||
Defrost control |
Mode | Automatic timing defrost, also can manual control | |||||
Interval |
0~99 ( set 24 hours when leaving factory ) |
||||||
Duration |
0~99 ( set 20 minutes when leaving factory ) |
||||||
Dimension L x W x H | 730x425x490 | 730x425x490 | 1130x425x490 | 1130x425x490 | 1130 x425x490 | ||
Weight | kg | ~40 | ~71 | ~110 | ~135 | ~150 |
The Picture of HUC LUC Marine Air Cooler Unit